Paper
1 August 1991 Magneto-optical apparatus with comparator for the measurement of large direct current
Zhipeng Zhang, Zhi Zhao, Baoxin Chong
Author Affiliations +
Proceedings Volume 1572, International Conference on Optical Fibre Sensors in China OFS(C) '91; (1991) https://doi.org/10.1117/12.49999
Event: International Conference on Optical Fibre Sensors in China, 1991, Wuhan, China
Abstract
This paper mainly deals with a novel magneto-optical apparatus with a comparator for the measurement of large direct current. The measuring principle, the probe structure, as well as the experimental data are presented in detail with additional analysis of the apparatus's mathematic model. A long-running test shows that the apparatus, with its measuring range from 6000 angstroms to 16,000 angstroms and its measuring error less than 0.5%, possesses a fine temperature characteristic and long-period performance stability.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhipeng Zhang, Zhi Zhao, and Baoxin Chong "Magneto-optical apparatus with comparator for the measurement of large direct current", Proc. SPIE 1572, International Conference on Optical Fibre Sensors in China OFS(C) '91, (1 August 1991); https://doi.org/10.1117/12.49999
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetism

Silicon

Optical fibers

Sensors

Beryllium

Control systems

Data modeling

RELATED CONTENT

Current transducers used in power line measurements
Proceedings of SPIE (August 19 2014)
Solid state neutron polarizers and collimators
Proceedings of SPIE (November 08 2001)
Measurement of fibre Verdet constant with twist method
Proceedings of SPIE (August 01 1991)
Investigation of magneto-optic effects in optical fibers
Proceedings of SPIE (April 14 2003)

Back to Top