Paper
2 July 1994 Pulsed eddy-current characterization of corrosion in aircraft lap splices: quantitative modeling
James H. Rose, Erol Uzal, John C. Moulder
Author Affiliations +
Proceedings Volume 2160, Superconductive Devices and Circuits; (1994) https://doi.org/10.1117/12.180999
Event: OE/LASE '94, 1994, Los Angeles, CA, United States
Abstract
Pulsed eddy-current detection and characterization of wall- thinning in aircraft lap-splices due to corrosion is studied theoretically. The relevant lap-splices consist of two one mm thick sheets of aluminum bonded together by bolts and separated a small distance by a insulating sealant. Corrosion changes the thickness of both plates and the size of the gap between them. The problem is to determine nondestructively the thickness of both the 'top' and 'bottom' plates as well as the intervening gap. We calculate the time-domain current-voltage response function of a small cylindrically symmetric coil of wire that is placed next to a lap-joint and excited by a step-function current. The result for air-core coils is obtained as a simple quadrature, while coils that contain ferrite-cores are modeled with a finite element code. The characteristic features of the transient response are shown to depend sensitively on the thickness of the top plate, the gap and the bottom plate.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James H. Rose, Erol Uzal, and John C. Moulder "Pulsed eddy-current characterization of corrosion in aircraft lap splices: quantitative modeling", Proc. SPIE 2160, Superconductive Devices and Circuits, (2 July 1994); https://doi.org/10.1117/12.180999
Lens.org Logo
CITATIONS
Cited by 22 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Corrosion

Aluminum

Solids

Signal to noise ratio

Spatial resolution

Signal attenuation

Fourier transforms

RELATED CONTENT


Back to Top