Paper
19 January 1996 Intensity measurement of automotive headlamps using a photometric vision system
Balvant Patel, Jose Cruz, David L. Perry, Frederic G. Himebaugh
Author Affiliations +
Abstract
Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Balvant Patel, Jose Cruz, David L. Perry, and Frederic G. Himebaugh "Intensity measurement of automotive headlamps using a photometric vision system", Proc. SPIE 2599, Three-Dimensional and Unconventional Imaging for Industrial Inspection and Metrology, (19 January 1996); https://doi.org/10.1117/12.230395