Paper
19 January 2006 A microfabricated device with integrated nanoelectrospray source for capillary electrophoresis and mass spectrometry
Min-Su Kim, Hwang-soo Joo, Byung-Gee Kim, Hoseong Kim, Yong-Kweon Kim
Author Affiliations +
Proceedings Volume 6036, BioMEMS and Nanotechnology II; 60361K (2006) https://doi.org/10.1117/12.638735
Event: Microelectronics, MEMS, and Nanotechnology, 2005, Brisbane, Australia
Abstract
In this study, a new method is described for integrating an electrospray ionization interface to a mass spectrometer with a capillary electrophoresis channel. We have fabricated the ESI-MS device composed of the metal emitter tip, allowing the generation of an efficient nanospray for protein detection, and CE separation channel monolithically in a glass microchip. A triangular-shaped gold emitter tip was formed by electroplating at the end of the separation channel. As an ESI source, this emitter structure aided the formation of a stable Taylor cone. It is easily fabricated by MEMS technology and more robust than that of silica or polymer recently reported. Moreover, this approach is less involved than applying a conductive coating to the exit end to establish electrical contact. As such, the interface is less dependent upon the longevity or durability of such coating, factors that have been consideration in the sheathless interfaces. The spraying stability was evaluated and the ESI-MS experiment was performed by spraying standard peptides for mass spectrometric analysis. The spraying was stable, with a relative standard deviation of 2.9%. The CE/ESI-MS analysis was performed by separating and spraying standard peptide mixture of Bradykinin 1-5, Bradykinin 1-8, and Angiotensin I. Each peptide was separated successfully and singly-charged peaks and doubly-charged peaks of each peptide were detected, respectively. Direct comparisons with conventional ESI-MS system using glass or fused silica emitters showed very similar performance with respect to signal intensity and stability.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Min-Su Kim, Hwang-soo Joo, Byung-Gee Kim, Hoseong Kim, and Yong-Kweon Kim "A microfabricated device with integrated nanoelectrospray source for capillary electrophoresis and mass spectrometry", Proc. SPIE 6036, BioMEMS and Nanotechnology II, 60361K (19 January 2006); https://doi.org/10.1117/12.638735
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glasses

Spectroscopy

Liquids

Gold

Microfluidics

Capillaries

Metals

Back to Top