DUV light source availability improvement via further enhancement of gas management technologies

Proc. SPIE 7973, 797327 (2011); http://dx.doi.org/10.1117/12.880155

Tuesday 1 March 2011
San Jose, California, USA
Optical Microlithography XXIV
Mircea V. Dusa
Daniel J. Riggs, Kevin O'Brien, and Daniel J. W. Brown

Cymer, Inc. (USA)

The continuous evolution of the semiconductor market necessitates ever-increasing improvements in DUV light source uptime as defined in the SEMI E10 standard. Cymer is developing technologies to exceed current and projected light source availability requirements via significant reduction in light source downtime. As an example, consider discharge chamber gas management functions which comprise a sizable portion of DUV light source downtime. Cymer's recent introduction of Gas Lifetime Extension (GLXTM) as a productivity improvement technology for its DUV lithography light sources has demonstrated noteworthy reduction in downtime. This has been achieved by reducing the frequency of full gas replenishment events from once per 100 million pulses to as low as once per 2 billion pulses. Cymer has continued to develop relevant technologies that target further reduction in downtime associated with light source gas management functions. Cymer's current subject is the development of technologies to reduce downtime associated with gas state optimization (e.g. total chamber gas pressure) and gas life duration. Current gas state optimization involves execution of a manual procedure at regular intervals throughout the lifetime of light source core components. Cymer aims to introduce a product enhancement - iGLXTM - that eliminates the need for the manual procedure and, further, achieves 4 billion pulse gas lives. Projections of uptime on DUV light sources indicate that downtime associated with gas management will be reduced by 70% when compared with GLX2. In addition to reducing downtime, iGLX reduces DUV light source cost of operation by constraining gas usage. Usage of fluorine rich Halogen gas mix has been reduced by 20% over GLX2.

© 2011 COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

History
Online Mar 22, 2011
Citation
Daniel J. Riggs, Kevin O'Brien and Daniel J. W. Brown, "DUV light source availability improvement via further enhancement of gas management technologies", Proc. SPIE 7973, 797327 (2011); http://dx.doi.org/10.1117/12.880155

DOWNLOAD ARTICLE

LOG IN or SELECT A PURCHASE OPTION:

RELATED CONTENT

More Like This Article


For access to fully linked references, you need to log in.

Close

close