PROCEEDINGS VOLUME 10411
EUROPEAN CONFERENCES ON BIOMEDICAL OPTICS | 25-29 JUNE 2017
Clinical and Preclinical Optical Diagnostics
Proceedings Volume 10411 is from: Logo
EUROPEAN CONFERENCES ON BIOMEDICAL OPTICS
25-29 June 2017
Munich, Germany
Front Matter: Vol. 10411
Proc. SPIE 10411, Front Matter: Volume 10411, 1041101 (28 August 2017); doi: 10.1117/12.2292243
Novel Microscopic Methods
Proc. SPIE 10411, Probing energy metabolism and microviscosity in cancer using FLIM, 1041102 (28 July 2017); doi: 10.1117/12.2287094
Proc. SPIE 10411, Efficiency enhancement of Raman microspectroscopy at long working distance by parabolic reflector, 1041103 (28 July 2017); doi: 10.1117/12.2281826
Proc. SPIE 10411, Studying the effect of photodynamic therapy (PDT) to enhance healing of femur fractures using polarimetric second-harmonic generation microscopy, 1041104 (28 July 2017); doi: 10.1117/12.2284430
Physiological Monitoring
Proc. SPIE 10411, Influence of the measuring condition on vibrocardiographic signals acquired on the thorax with a laser Doppler vibrometer, 1041105 (28 July 2017); doi: 10.1117/12.2282894
Proc. SPIE 10411, Investigating optical path in reflectance pulse oximetry using a multilayer Monte Carlo model, 1041106 (28 July 2017); doi: 10.1117/12.2281612
Proc. SPIE 10411, Thyroid tissue constituents characterization and application to in vivo studies by broadband (600-1200 nm) diffuse optical spectroscopy, 1041107 (28 July 2017); doi: 10.1117/12.2287179
Multispectral Imaging
Proc. SPIE 10411, Photoaging evaluation by RGB images using a smartphone for photodynamic therapy assessment, 1041108 (28 July 2017); doi: 10.1117/12.2283246
Proc. SPIE 10411, Diagnosing hypoxia in murine models of rheumatoid arthritis from reflectance multispectral images, 1041109 (28 July 2017); doi: 10.1117/12.2286087
Proc. SPIE 10411, A multispectral endoscope based on spectrally resolved detector arrays, 104110A (28 July 2017); doi: 10.1117/12.2283398
Proc. SPIE 10411, Multi-spectral endogenous fluorescence imaging for bacterial differentiation, 104110B (28 July 2017); doi: 10.1117/12.2285065
Neurophotonics
Proc. SPIE 10411, Interventional fluorescence spectroscopy: preliminary results to detect tumor margins during glioma resection with two fluorescence spectra of PpIX , 104110C (28 July 2017); doi: 10.1117/12.2286110
Endoscopic and Intra-operative Imaging I
Proc. SPIE 10411, Bioinspired second harmonic generation, 104110D (28 July 2017); doi: 10.1117/12.2286120
Proc. SPIE 10411, Multimodal fiber-probe spectroscopy as a clinical tool for diagnosing and classifying biological tissues, 104110E (28 July 2017); doi: 10.1117/12.2283278
Therapy Response
Proc. SPIE 10411, Optical imaging and spectroscopy of microenvironmental changes associated with radiation resistance in tumors, 104110G (28 July 2017); doi: 10.1117/12.2286283
Proc. SPIE 10411, A fluorescence model of the murine lung for optical detection of pathogenic bacteria, 104110H (28 July 2017); doi: 10.1117/12.2285926
Proc. SPIE 10411, Optical measurement of blood flow in exercising skeletal muscle: a pilot study, 104110I (28 July 2017); doi: 10.1117/12.2285447
Endoscopic and Intra-operative Imaging II
Proc. SPIE 10411, Multiparameter solid phantom for fluorescence imaging standardization , 104110J (28 July 2017); doi: 10.1117/12.2286059
Proc. SPIE 10411, Towards real-time quantitative optical imaging for surgery, 104110K (28 July 2017); doi: 10.1117/12.2285774
In vitro Sensing and Image Analysis
Proc. SPIE 10411, Evaluation of an optoacoustic based gas analysing device, 104110L (28 July 2017); doi: 10.1117/12.2286109
Proc. SPIE 10411, Micro-Raman spectroscopy for identification and classification of UTI bacteria, 104110M (28 July 2017); doi: 10.1117/12.2282469
Proc. SPIE 10411, Tasked-based quantification of measurement utility for ex vivo multi-spectral Mueller polarimetry of the uterine cervix, 104110N (28 July 2017); doi: 10.1117/12.2286837
Proc. SPIE 10411, Global adjustment for creating extended panoramic images in video-dermoscopy, 104110O (28 July 2017); doi: 10.1117/12.2286111
Proc. SPIE 10411, Automated skin lesion segmentation with kernel density estimation, 104110P (28 July 2017); doi: 10.1117/12.2283038
Head & Neck Optical Guided Surgery: Workshop by Head & Neck Optical Diagnostic Society
Proc. SPIE 10411, Neurosurgical sapphire handheld probe for intraoperative optical diagnostics, laser coagulation and aspiration of malignant brain tissue, 104110Q (28 July 2017); doi: 10.1117/12.2286124
Poster Session
Proc. SPIE 10411, Study of extracerebral contamination for three cerebral oximeters by Monte Carlo simulation using CT data, 104110R (28 July 2017); doi: 10.1117/12.2281276
Proc. SPIE 10411, Estimation of individual response in finger blood concentration change under occlusion on human arm using speckle patterns, 104110S (28 July 2017); doi: 10.1117/12.2283517
Proc. SPIE 10411, Comparison of remote photoplethysmography signals acquired by ultra-low noise camera and conventional camera during physiological tests, 104110T (28 July 2017); doi: 10.1117/12.2284657
Proc. SPIE 10411, Multimodal OCT for complex assessment of tumors response to therapy, 104110U (28 July 2017); doi: 10.1117/12.2285170
Proc. SPIE 10411, Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma, 104110V (28 July 2017); doi: 10.1117/12.2282888
Proc. SPIE 10411, OCT inspection of degenerative and rheumatic tendinous cords, 104110W (28 July 2017); doi: 10.1117/12.2283039
Proc. SPIE 10411, Oxygenation level and hemoglobin concentration in experimental tumor estimated by diffuse optical spectroscopy, 104110X (28 July 2017); doi: 10.1117/12.2284793
Proc. SPIE 10411, A classification model for non-alcoholic steatohepatitis (NASH) using confocal Raman micro-spectroscopy, 104110Y (28 July 2017); doi: 10.1117/12.2281445
Back to Top