PROCEEDINGS VOLUME 2136
OE/LASE '94 | 23-29 JANUARY 1994
Biochemical Diagnostic Instrumentation
IN THIS VOLUME

0 Sessions, 38 Papers, 0 Presentations
OE/LASE '94
23-29 January 1994
Los Angeles, CA, United States
Blood Components and Measurement
Proc. SPIE 2136, Determination of the blood oxygenation in the brain by time-resolved reflectance spectroscopy: contribution of vascular absorption and tissue background absorption, 0000 (21 July 1994); doi: 10.1117/12.180773
Proc. SPIE 2136, Determination of blood oxygenation in the brain by time-resolved reflectance spectroscopy: influence of the skin, skull, and meninges, 0000 (21 July 1994); doi: 10.1117/12.180783
Proc. SPIE 2136, Spatial localization of absorbing zones in a turbid media using NIR CW lasers, 0000 (21 July 1994); doi: 10.1117/12.180794
Proc. SPIE 2136, Image analysis of the blood cells for cytomorphodiagnostics and control of the effectiveness treatment, 0000 (21 July 1994); doi: 10.1117/12.180806
Proc. SPIE 2136, Laser-based blood cell measurements for the biological reconstruction of ionizing radiation doses using a novel technique for cytometry/biochemical reaction analysis, 0000 (21 July 1994); doi: 10.1117/12.180807
Optical Diagnosis
Proc. SPIE 2136, Laser Doppler perfusion monitoring and imaging of blood microcirculation, 0000 (21 July 1994); doi: 10.1117/12.180808
Proc. SPIE 2136, Blood flow velocity measurements in rat mesentery arterioles in health and under hypertensive conditions, 0000 (21 July 1994); doi: 10.1117/12.180809
Proc. SPIE 2136, Investigation of focused Gaussian beam diffraction in narrow capillaries, 0000 (21 July 1994); doi: 10.1117/12.180810
Proc. SPIE 2136, Biodiagnostics with multiplex dyes, 0000 (21 July 1994); doi: 10.1117/12.180774
Proc. SPIE 2136, Aggregation and deformation of red blood cells as probed by a laser light scattering technique in a concentrated suspension: methodology, 0000 (21 July 1994); doi: 10.1117/12.180775
Proc. SPIE 2136, Aggregation and deformation of red blood cells as probed by a laser light scattering technique in a concentrated suspension: comparison between normal and pathological red blood cells, 0000 (21 July 1994); doi: 10.1117/12.180776
Proc. SPIE 2136, Discrimination between orientation and elongation of RBC in laminar flow by means of laser diffraction, 0000 (21 July 1994); doi: 10.1117/12.180777
Proc. SPIE 2136, Experience of application of nephelometry for the analyses of aggregational state of blood in a clinic of internal diseases, 0000 (21 July 1994); doi: 10.1117/12.180778
Proc. SPIE 2136, Diffractometric control in erythrocyte damage low-energy laser treatment, 0000 (21 July 1994); doi: 10.1117/12.180779
Poster Session
Proc. SPIE 2136, Novel optical method for measuring D-glucose 6-phosphate, 0000 (21 July 1994); doi: 10.1117/12.180780
Proc. SPIE 2136, Substrate-induced quenching-based measurement of glycerol, 0000 (21 July 1994); doi: 10.1117/12.180781
Proc. SPIE 2136, Theoretical assessment of the correlation function of the laser Doppler anemometer signal from the blood circulation in the eye retina, 0000 (21 July 1994); doi: 10.1117/12.180782
Optical Diagnosis
Proc. SPIE 2136, Diagnostics of physiological states of organism by means of fluorescent measurement of membrane potential of blood cells, 0000 (21 July 1994); doi: 10.1117/12.180784
Poster Session
Proc. SPIE 2136, Computerized morphodensitometric analysis of blood cells from individuals exposed to low-dose radiation, 0000 (21 July 1994); doi: 10.1117/12.180785
Instrument Techniques
Proc. SPIE 2136, Emerging biomedical applications of time-resolved fluorescence spectroscopy, 0000 (21 July 1994); doi: 10.1117/12.180786
Proc. SPIE 2136, Modern equilibrium ultracentrifugation: applications of automated interferometry, 0000 (21 July 1994); doi: 10.1117/12.180787
Proc. SPIE 2136, Overview of a novel point of care instrument system for measuring whole blood Prothrombin time, 0000 (21 July 1994); doi: 10.1117/12.180788
Proc. SPIE 2136, Instrument factors influencing the precision of measurement of clinical spectrometers, 0000 (21 July 1994); doi: 10.1117/12.180789
Proc. SPIE 2136, New optics method of low-concentration particles detection in liquids, 0000 (21 July 1994); doi: 10.1117/12.180790
Diagnostic Assays and Chemistries
Proc. SPIE 2136, Ultrasensitive near-IR fluorescence detection in capillary zone electrophoresis, 0000 (21 July 1994); doi: 10.1117/12.180791
Proc. SPIE 2136, Production, fixation, and staining of cells on slides for maximum photometric sensitivity, 0000 (21 July 1994); doi: 10.1117/12.180792
Proc. SPIE 2136, Possible clinical applications for direct molecular charge determination by equilibrium electrophoresis, 0000 (21 July 1994); doi: 10.1117/12.180793
Proc. SPIE 2136, Detection and analysis of leptospiral DNA in early Leptospirosis by polymerase chain reaction and DNA hybridization with Digoxingenin-AMPPD, 0000 (21 July 1994); doi: 10.1117/12.180795
Proc. SPIE 2136, Room-temperature phosphorescence of metalloporphyrins and its application to immunoassay, 0000 (21 July 1994); doi: 10.1117/12.180796
Proc. SPIE 2136, Ultrasensitive intracavity molecular spectroscopy for diagnostic applications, 0000 (21 July 1994); doi: 10.1117/12.180797
Diagnostic Systems
Proc. SPIE 2136, New compact TCSPC apparatus based on sub 15 ps laserdiodes: preliminary results, 0000 (21 July 1994); doi: 10.1117/12.180798
Proc. SPIE 2136, Ultrasensitive Schlieren optical system, 0000 (21 July 1994); doi: 10.1117/12.180799
Proc. SPIE 2136, Lifetime-based optical sensing of pH using resonance energy transfer in sol-gel sensors, 0000 (21 July 1994); doi: 10.1117/12.180800
Sensor Technologies
Proc. SPIE 2136, New small-diameter fiber optic absorbance sensor for continuous spectral scanning, 0000 (21 July 1994); doi: 10.1117/12.180801
Proc. SPIE 2136, Sensitive absorption measurements of 99mTc imaging agents using a new fiber optic sensor, 0000 (21 July 1994); doi: 10.1117/12.180802
Proc. SPIE 2136, Large-area waveguide sensor for multiple analytes detection, 0000 (21 July 1994); doi: 10.1117/12.180803
Poster Session
Proc. SPIE 2136, Dielectro-deformational spectroscopy of erythrocytes, 0000 (21 July 1994); doi: 10.1117/12.180804
Instrument Techniques
Proc. SPIE 2136, Ultrasensitive fluorescence detection and maximum likelihood method, 0000 (21 July 1994); doi: 10.1117/12.180805
Back to Top