PROCEEDINGS VOLUME 2432
MEDICAL IMAGING 1995 | 26 FEBRUARY - 2 MARCH 1995
Medical Imaging 1995: Physics of Medical Imaging
MEDICAL IMAGING 1995
26 February - 2 March 1995
San Diego, CA, United States
Image Quality and X-Ray Physics I
Proc. SPIE 2432, Quantifying the efficiency of imaging systems: a decade of progress in optimizing screen-films for x-ray detection, 0000 (8 May 1995); doi: 10.1117/12.208328
Proc. SPIE 2432, Simulation of the imaging performance of x-ray image intensifier/TV camera chains, 0000 (8 May 1995); doi: 10.1117/12.208339
Proc. SPIE 2432, Investigation of coherent-scatter computed tomography, 0000 (8 May 1995); doi: 10.1117/12.208349
Proc. SPIE 2432, Sensitivity of radiographic screens to scattered radiation, 0000 (8 May 1995); doi: 10.1117/12.208360
Image Quality and X-Ray Physics II
Proc. SPIE 2432, From the finite-length line-spread function to the point-spread function, 0000 (8 May 1995); doi: 10.1117/12.208370
Proc. SPIE 2432, Comparison of high-MTF and reduced-noise radiographic imaging systems, 0000 (8 May 1995); doi: 10.1117/12.208379
Proc. SPIE 2432, Statistical processes limiting the noise of a screen-film system: II, 0000 (8 May 1995); doi: 10.1117/12.208385
Proc. SPIE 2432, Risk assessment from automated feature analysis of digitized mammograms, 0000 (8 May 1995); doi: 10.1117/12.208386
Proc. SPIE 2432, Digital mammography: tradeoffs between 50- and 100-micron pixel size, 0000 (8 May 1995); doi: 10.1117/12.208387
Proc. SPIE 2432, Multiparameter optimization of mammography with alternative x-ray sources, 0000 (8 May 1995); doi: 10.1117/12.208329
Image Quality and X-Ray Physics III
Proc. SPIE 2432, Recent progress in noise reduction and scatter correction in dual-energy imaging, 0000 (8 May 1995); doi: 10.1117/12.208330
Proc. SPIE 2432, Effect of finite detector-element width on the spatial-frequency-dependent detective quantum efficiency, 0000 (8 May 1995); doi: 10.1117/12.208331
Proc. SPIE 2432, Quantitative error mapping of MR relaxation times, 0000 (8 May 1995); doi: 10.1117/12.208332
Proc. SPIE 2432, Estimation performance at low SNR: predictions of the Barankin bound, 0000 (8 May 1995); doi: 10.1117/12.208333
Proc. SPIE 2432, Use of scattered radiation in radioisotope imaging, 0000 (8 May 1995); doi: 10.1117/12.208334
Physics of Ultrasound Imaging
Proc. SPIE 2432, Three-dimensional ultrasound imaging, 0000 (8 May 1995); doi: 10.1117/12.208335
Proc. SPIE 2432, Towards the volumetricardiogram: volume determination of cardiac chambers using 3D matrix-array ultrasound, 0000 (8 May 1995); doi: 10.1117/12.208336
Proc. SPIE 2432, Simulation and analysis of the effects of strong scattering, 0000 (8 May 1995); doi: 10.1117/12.208337
Proc. SPIE 2432, Attenuation-weighted pulse-echo imaging with ultrasound, 0000 (8 May 1995); doi: 10.1117/12.208338
Novel Detectors for Digital Radiography I
Proc. SPIE 2432, Large-area flat-panel amorphous silicon imagers, 0000 (8 May 1995); doi: 10.1117/12.208340
Proc. SPIE 2432, Amorphous selenium liquid crystal light valve for x-ray imaging, 0000 (8 May 1995); doi: 10.1117/12.208341
Proc. SPIE 2432, New digital detector for projection radiography, 0000 (8 May 1995); doi: 10.1117/12.208342
Proc. SPIE 2432, Digital radiology using self-scanned readout of amorphous selenium: design considerations for mammography, 0000 (8 May 1995); doi: 10.1117/12.208343
Proc. SPIE 2432, MTF measurements with high-resolution a-Si:H imaging arrays, 0000 (8 May 1995); doi: 10.1117/12.208344
Novel Detectors for Digital Radiography II
Proc. SPIE 2432, Correction of image intensifier distortion for three-dimensional x-ray angiography, 0000 (8 May 1995); doi: 10.1117/12.208345
Proc. SPIE 2432, Image intensifier-based volume tomographic angiography imaging system: system evaluation, 0000 (8 May 1995); doi: 10.1117/12.208346
Proc. SPIE 2432, Development of a 3D CT scanner using cone beam, 0000 (8 May 1995); doi: 10.1117/12.208347
Proc. SPIE 2432, Blood vessel reconstruction from a limited number of cone-beam projections: application to cerebral blood vessel projections and to an excised animal heart, 0000 (8 May 1995); doi: 10.1117/12.208348
Proc. SPIE 2432, Effect of helical pitch and collimation on tumor contrast and slice profile in helical CT imaging, 0000 (8 May 1995); doi: 10.1117/12.208350
Proc. SPIE 2432, Nonlinear control of charge-coupled device sensors, 0000 (8 May 1995); doi: 10.1117/12.208351
Novel Detectors for Digital Radiography III
Proc. SPIE 2432, Ion-polar collisions in gas-filled KCD imaging detectors, 0000 (8 May 1995); doi: 10.1117/12.208352
Proc. SPIE 2432, Real-time portal imaging devices operating on high-pressure gaseous electronic principles, 0000 (8 May 1995); doi: 10.1117/12.208353
Proc. SPIE 2432, Use of mixed media to improve the performance of kinestatic charge detectors, 0000 (8 May 1995); doi: 10.1117/12.208354
Proc. SPIE 2432, Combined SPECT and x-ray CT medical imaging system, 0000 (8 May 1995); doi: 10.1117/12.208355
Proc. SPIE 2432, Performance evaluation of image-intensifier-TV fluoroscopy systems, 0000 (8 May 1995); doi: 10.1117/12.208356
Digital Radiography System Performance
Proc. SPIE 2432, Solid state detector for slit-scan mammography, 0000 (8 May 1995); doi: 10.1117/12.208357
Proc. SPIE 2432, Solid state x-ray detectors for digital mammography, 0000 (8 May 1995); doi: 10.1117/12.208358
Proc. SPIE 2432, Imaging performance of a large-field kinestatic charge detector for digital radiography, 0000 (8 May 1995); doi: 10.1117/12.208359
Proc. SPIE 2432, Clinical evaluation of CR versus plain film for neonatal ICU applications, 0000 (8 May 1995); doi: 10.1117/12.208361
Proc. SPIE 2432, Quantitative analysis of imaging performance for computed radiography systems, 0000 (8 May 1995); doi: 10.1117/12.208362
Poster Session
Proc. SPIE 2432, Preliminary experience with monoenergetic photon mammography, 0000 (8 May 1995); doi: 10.1117/12.208363
Proc. SPIE 2432, Preliminary characterizations of a new hybrid CdTe structure for x-ray dental imaging, 0000 (8 May 1995); doi: 10.1117/12.208364
Proc. SPIE 2432, High-resolution x-ray imaging with a Gd2O3(Eu) transparent ceramic scintillator, 0000 (8 May 1995); doi: 10.1117/12.208365
Proc. SPIE 2432, High-luminance fluorescent screen with interference filter, 0000 (8 May 1995); doi: 10.1117/12.208366
Proc. SPIE 2432, Performance characteristics of high-resolution charge-coupled device film digitizers, 0000 (8 May 1995); doi: 10.1117/12.208367
Proc. SPIE 2432, Development of large field of view and high-definition real-time digital radiography system, 0000 (8 May 1995); doi: 10.1117/12.208368
Proc. SPIE 2432, Digital mammography: the effects of decreased exposure, 0000 (8 May 1995); doi: 10.1117/12.208369
Proc. SPIE 2432, Resolution performance of a 2000-line system for digital fluoroscopy, 0000 (8 May 1995); doi: 10.1117/12.208371
Proc. SPIE 2432, Computed radiography acceptance testing, 0000 (8 May 1995); doi: 10.1117/12.208372
Proc. SPIE 2432, Fundamental statistics of the imaging process, 0000 (8 May 1995); doi: 10.1117/12.208373
Proc. SPIE 2432, High-resolution (1k x 1k) progressive real-time CCD image sensor for radiology systems, 0000 (8 May 1995); doi: 10.1117/12.208374
Proc. SPIE 2432, Quality assurance for CT and MRI scanners, 0000 (8 May 1995); doi: 10.1117/12.208375
Proc. SPIE 2432, 3D transvaginal ultrasound imaging for identification of endometrial abnormality, 0000 (8 May 1995); doi: 10.1117/12.208376
Proc. SPIE 2432, Cost-effective, high-resolution, portable digital x-ray imager, 0000 (8 May 1995); doi: 10.1117/12.208377
Proc. SPIE 2432, Quality control on storage phosphor digital radiography system, 0000 (8 May 1995); doi: 10.1117/12.208378
Proc. SPIE 2432, Performance and maintenance of storage phosphor plates and cassettes in digital radiography, 0000 (8 May 1995); doi: 10.1117/12.208380
Proc. SPIE 2432, Objective measures of quality assurance in a computed radiography-based radiology department, 0000 (8 May 1995); doi: 10.1117/12.208381