PROCEEDINGS VOLUME 3336
MEDICAL IMAGING '98 | 21-26 FEBRUARY 1998
Medical Imaging 1998: Physics of Medical Imaging
IN THIS VOLUME

0 Sessions, 86 Papers, 0 Presentations
MEDICAL IMAGING '98
21-26 February 1998
San Diego, CA, United States
X-Ray Detectors I
Proc. SPIE 3336, Large-area 97-um pitch indirect-detection active-matrix flat-panel imager (AMFPI), 0000 (24 July 1998); doi: 10.1117/12.317006
Proc. SPIE 3336, Improved imaging performance of a 14"x17" direct radiography system using a Se/TFT detector, 0000 (24 July 1998); doi: 10.1117/12.317017
Proc. SPIE 3336, Large-area x-ray image sensing using a Pbl2 photoconductor, 0000 (24 July 1998); doi: 10.1117/12.317027
Proc. SPIE 3336, Technical and clinical results of an experimental flat dynamic (digital) x-ray image detector (FDXD) system with real-time corrections, 0000 (24 July 1998); doi: 10.1117/12.317038
Proc. SPIE 3336, New CsI/a-Si 17" x 17" x-ray flat-panel detector provides superior detectivity and immediate direct digital output for general radiography systems, 0000 (24 July 1998); doi: 10.1117/12.317049
X-Ray Physics
Proc. SPIE 3336, Diffraction spectrometer for spectral analysis of mammographic x-ray sources, 0000 (24 July 1998); doi: 10.1117/12.317059
Proc. SPIE 3336, Resolution properties of a large-area quasi-monochromatic x-ray source for mammography, 0000 (24 July 1998); doi: 10.1117/12.317069
Proc. SPIE 3336, Monochromatic plasma x-ray generator and its applications, 0000 (24 July 1998); doi: 10.1117/12.317079
Proc. SPIE 3336, Energy-selective laser-based x-ray source for mammography, 0000 (24 July 1998); doi: 10.1117/12.317088
Proc. SPIE 3336, High-resolution scanned-slit x-ray imaging using a refractive lens for x-ray focusing, 0000 (24 July 1998); doi: 10.1117/12.317007
Non-Ionizing Imaging
Proc. SPIE 3336, Investigation of an acoustical holography system for real-time imaging, 0000 (24 July 1998); doi: 10.1117/12.317008
Proc. SPIE 3336, Three-dimensional ultrasound imaging of the prostate, 0000 (24 July 1998); doi: 10.1117/12.317009
Proc. SPIE 3336, Propagation and imaging of wideband three-dimensional ultrasound fields, 0000 (24 July 1998); doi: 10.1117/12.317010
Proc. SPIE 3336, Local motion suppression in magnetic resonance imaging, 0000 (24 July 1998); doi: 10.1117/12.317011
Proc. SPIE 3336, Reconstruction aspects of spiral scan magnetic resonance imaging, 0000 (24 July 1998); doi: 10.1117/12.317012
X-Ray Detectors II
Proc. SPIE 3336, Advanced clinical KCD scanner for digital radiography, 0000 (24 July 1998); doi: 10.1117/12.317013
Proc. SPIE 3336, Flat-panel detector, CCD cameras, and electron-beam-tube-based video for use in portal imaging, 0000 (24 July 1998); doi: 10.1117/12.317014
Proc. SPIE 3336, Portal imaging with a CsI(Tl) transparent scintillator x-ray detector, 0000 (24 July 1998); doi: 10.1117/12.317015
Proc. SPIE 3336, Image quality of scintillator-based x-ray electronic imagers, 0000 (24 July 1998); doi: 10.1117/12.317016
Proc. SPIE 3336, Electronic portal imaging device (EPID) based on a novel camera with avalanche multiplication, 0000 (24 July 1998); doi: 10.1117/12.317018
Mammographic Imaging
Proc. SPIE 3336, Integrated CMOS-selenium x-ray detector for digital mammography, 0000 (24 July 1998); doi: 10.1117/12.317019
Proc. SPIE 3336, Technique to improve the effective fill factor of digital mammographic imagers, 0000 (24 July 1998); doi: 10.1117/12.317020
Imaging Theory
Proc. SPIE 3336, Linear-systems modeling of parallel cascaded stochastic processes: the NPS of radiographic screens with reabsorption of characteristic x-radiation, 0000 (24 July 1998); doi: 10.1117/12.317021
Proc. SPIE 3336, Prewhitening matched filter: practical implementation, SNR estimation, and bias reduction, 0000 (24 July 1998); doi: 10.1117/12.317022
Proc. SPIE 3336, Simplified method of estimating noise-power spectra, 0000 (24 July 1998); doi: 10.1117/12.317023
Proc. SPIE 3336, Synthesizing a parallel-projection image from pinhole data, 0000 (24 July 1998); doi: 10.1117/12.317024
Proc. SPIE 3336, Image quantization: statistics and modeling, 0000 (24 July 1998); doi: 10.1117/12.317025
Volume Imaging
Proc. SPIE 3336, Region-of-interest cone-beam CT with a spiral scan, 0000 (24 July 1998); doi: 10.1117/12.317026
Proc. SPIE 3336, New classes of helical weighting algorithms with applications to fast CT reconstruction, 0000 (24 July 1998); doi: 10.1117/12.317028
Proc. SPIE 3336, Improving the temporal response of computed tomography fluoroscopy, 0000 (24 July 1998); doi: 10.1117/12.317029
Proc. SPIE 3336, Computed rotational angiography: system performance assessment using in-vitro and in-vivo models, 0000 (24 July 1998); doi: 10.1117/12.317030
Proc. SPIE 3336, Selenium flat-panel detector-based volume tomographic angiography imaging: phantom studies, 0000 (24 July 1998); doi: 10.1117/12.317031
Imaging Physics
Proc. SPIE 3336, Effect of secondary radiations on the performance of digital radiographic detectors, 0000 (24 July 1998); doi: 10.1117/12.317032
Proc. SPIE 3336, Influence of scatter reduction on lesion signal-to-noise ratio and lesion detection in digital chest radiography, 0000 (24 July 1998); doi: 10.1117/12.317033
Proc. SPIE 3336, Flat-field correction technique for digital detectors, 0000 (24 July 1998); doi: 10.1117/12.317034
Proc. SPIE 3336, Signal-to-noise ratio and radiation dose as a function of photon energy in mammography, 0000 (24 July 1998); doi: 10.1117/12.317035
Proc. SPIE 3336, Three-dimensional coded-aperture techniques in diagnostic nuclear medicine imaging, 0000 (24 July 1998); doi: 10.1117/12.317036
Real-Time X-Ray Detectors
Proc. SPIE 3336, Flat-panel imaging system for fluoroscopy applications, 0000 (24 July 1998); doi: 10.1117/12.317037
Proc. SPIE 3336, Development of a selenium-based flat-panel detector for real-time radiography and fluoroscopy, 0000 (24 July 1998); doi: 10.1117/12.317039
Proc. SPIE 3336, Dynamic x-ray imaging system based on an amorphous silicon thin-film array, 0000 (24 July 1998); doi: 10.1117/12.317040
Proc. SPIE 3336, Detective quantum efficiency of direct flat-panel x-ray imaging detectors for fluoroscopy, 0000 (24 July 1998); doi: 10.1117/12.317041
Proc. SPIE 3336, Real-time diagnostic imaging with a novel x-ray detector with multiple screen-CCD sensors, 0000 (24 July 1998); doi: 10.1117/12.317042
Proc. SPIE 3336, Physical image quality evaluation of a CCD-based x-ray image intensifier digital fluorography system for cardiac applications, 0000 (24 July 1998); doi: 10.1117/12.317043
X-Ray Detectors III
Proc. SPIE 3336, New amorphous-silicon image sensor for x-ray diagnostic medical imaging applications, 0000 (24 July 1998); doi: 10.1117/12.317044
Proc. SPIE 3336, Novel large-area MIS-type x-ray image sensor for digital radiography, 0000 (24 July 1998); doi: 10.1117/12.317045
Proc. SPIE 3336, Clinical evaluation of a full-field digital-projection radiography detector, 0000 (24 July 1998); doi: 10.1117/12.317046
Proc. SPIE 3336, New large-area x-ray image sensor, 0000 (24 July 1998); doi: 10.1117/12.317047
Proc. SPIE 3336, Screen design for flat-panel imagers in diagnostic radiology, 0000 (24 July 1998); doi: 10.1117/12.317048
Posters--Sunday/Monday
Proc. SPIE 3336, Digital radiology using amorphous selenium and active-matrix flat-panel readout: photoconductive gain and gain fluctuations, 0000 (24 July 1998); doi: 10.1117/12.317050
Proc. SPIE 3336, Selenium direct-converter structure for static and dynamic x-ray detection in medical imaging applications, 0000 (24 July 1998); doi: 10.1117/12.317051
Proc. SPIE 3336, Amorphous silicon dual-mode medical imaging system, 0000 (24 July 1998); doi: 10.1117/12.317052
Proc. SPIE 3336, Test results from a pixel readout chip for 2D dynamic x-ray imaging, 0000 (24 July 1998); doi: 10.1117/12.317053
Proc. SPIE 3336, Thin-film transistor array technology for high-performance direct-conversion x-ray sensors, 0000 (24 July 1998); doi: 10.1117/12.317054
Proc. SPIE 3336, Novel direct digital modular x-ray device and system, 0000 (24 July 1998); doi: 10.1117/12.317055
Proc. SPIE 3336, Detection characterization of Cd1-xZnxTe detectors for x-ray linear arrays, 0000 (24 July 1998); doi: 10.1117/12.317056
Proc. SPIE 3336, DQE and system optimization for indirect-detection flat-panel imagers in diagnostic radiology, 0000 (24 July 1998); doi: 10.1117/12.317057