Keynote Session
Proc. SPIE 6142, Low cost digital radiographic imaging systems: the x-ray light valve, 614203 (2 March 2006); doi: 10.1117/12.650195
Proc. SPIE 6142, A multi-beam x-ray imaging system based on carbon nanotube field emitters, 614204 (2 March 2006); doi: 10.1117/12.654006
Mammography
Proc. SPIE 6142, Applying the European protocol for the quality control of the physical and technical aspects of mammography screening threshold contrast visibility assessment to digital systems, 614205 (2 March 2006); doi: 10.1117/12.650141
Proc. SPIE 6142, Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems, 614206 (2 March 2006); doi: 10.1117/12.653296
Proc. SPIE 6142, Anatomically adaptable automatic exposure control (AEC) for amorphous selenium (<i>a</i>-Se) full field digital mammography (FFDM) system, 614207 (2 March 2006); doi: 10.1117/12.650279
Proc. SPIE 6142, Preliminary investigation of dose for a dedicated mammotomography system, 614208 (2 March 2006); doi: 10.1117/12.654095
Proc. SPIE 6142, Comparison of polychromatic and monochromatic x-rays for imaging, 614209 (2 March 2006); doi: 10.1117/12.651037
Proc. SPIE 6142, Optimization of operating conditions in photon-counting multi-slit mammography based on Si-strip detectors, 61420A (2 March 2006); doi: 10.1117/12.652728
Tomosynthesis
Proc. SPIE 6142, Evaluation of a photon-counting breast tomosynthesis imaging system, 61420B (2 March 2006); doi: 10.1117/12.654651
Proc. SPIE 6142, Quantification for contrast-enhanced digital breast tomosynthesis, 61420D (2 March 2006); doi: 10.1117/12.654682
Proc. SPIE 6142, Gaussian frequency blending algorithm with matrix inversion tomosynthesis (MITS) and filtered back projection (FBP) for better digital breast tomosynthesis reconstruction, 61420E (2 March 2006); doi: 10.1117/12.652264
Proc. SPIE 6142, Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device, 61420F (2 March 2006); doi: 10.1117/12.651380
X-ray CT: Cardiac
Proc. SPIE 6142, Motion artifacts from an inverse-geometry CT system with multiple detector arrays, 61420G (2 March 2006); doi: 10.1117/12.653863
Proc. SPIE 6142, Design considerations in cardiac CT, 61420H (2 March 2006); doi: 10.1117/12.651633
Proc. SPIE 6142, Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT, 61420I (2 March 2006); doi: 10.1117/12.653347
Proc. SPIE 6142, Toward time resolved 4D cardiac CT imaging with patient dose reduction: estimating the global heart motion, 61420J (2 March 2006); doi: 10.1117/12.653279
Proc. SPIE 6142, Optimized time window for cardiac CT reconstruction based on Doppler tissue imaging (DTI) data, 61420K (2 March 2006); doi: 10.1117/12.654348
Proc. SPIE 6142, ECG gated continuous circular cone-beam multi-cycle reconstruction for in-stent coronary artery imaging: a phantom study, 61420L (2 March 2006); doi: 10.1117/12.652011
Optical and MR Imaging
Proc. SPIE 6142, Impact of noise-on-image reconstruction for diffuse optical tomography, 61420M (2 March 2006); doi: 10.1117/12.651297
Proc. SPIE 6142, High-resolution multiphoton optical tomography of tissues: an in vitro and in vivo study, 61420N (2 March 2006); doi: 10.1117/12.651358
Proc. SPIE 6142, Generalized auto-calibrating technique for image reconstruction from sensitivity encoded MRI data, 61420O (2 March 2006); doi: 10.1117/12.654196
Proc. SPIE 6142, Reducing temporal fluctuations in MRI with the multichannel method SENSE, 61420P (2 March 2006); doi: 10.1117/12.654263
Proc. SPIE 6142, Description of statistical theory of magnetic resonance imaging (MRI), 61420Q (2 March 2006); doi: 10.1117/12.653635
X-ray Imaging Detectors I
Proc. SPIE 6142, Performance evaluation of dual-crystal APD-based detector modules for positron emission tomography, 61420R (2 March 2006); doi: 10.1117/12.653882
Proc. SPIE 6142, High voltage protection in active matrix flat-panel imagers, 61420S (2 March 2006); doi: 10.1117/12.655611
Proc. SPIE 6142, Low-noise pixel architecture for advanced diagnostic medical x-ray imaging applications, 61420T (2 March 2006); doi: 10.1117/12.654900
Proc. SPIE 6142, A new 2D-tiled detector for multislice CT, 61420U (2 March 2006); doi: 10.1117/12.653245
Proc. SPIE 6142, Novel CT detector based on an inorganic scintillator working in photon-counting mode, 61420V (2 March 2006); doi: 10.1117/12.654541
Proc. SPIE 6142, Three-dimensional columnar CsI model for x-ray imaging system simulations using MANTIS: validating for noise, blur, and light output, 61420W (2 March 2006); doi: 10.1117/12.653309
X-ray CT: Systems
Proc. SPIE 6142, Evaluation of noise and resolution properties of penalized-likelihood CT sinogram smoothing and restoration algorithms, 61420X (2 March 2006); doi: 10.1117/12.653855
Proc. SPIE 6142, Comparison of three sinogram restoration methods, 61420Y (2 March 2006); doi: 10.1117/12.652079
Proc. SPIE 6142, Investigation of image lag in a high-speed flat panel detector-based cone beam CT imaging system, 61420Z (2 March 2006); doi: 10.1117/12.655612
Proc. SPIE 6142, Design and development of C-arm based cone-beam CT for image-guided interventions: initial results, 614210 (2 March 2006); doi: 10.1117/12.653197
Proc. SPIE 6142, A novel cone beam breast CT scanner: preliminary system evaluation, 614211 (2 March 2006); doi: 10.1117/12.655741
Proc. SPIE 6142, Guidance for cone-beam CT design: tradeoff between view sampling rate and completeness of scanning trajectories, 614212 (28 February 2006); doi: 10.1117/12.653174
Innovative Imaging
Proc. SPIE 6142, Application of x-ray computed tomography based on the refraction contrast to biomedicine, 614213 (2 March 2006); doi: 10.1117/12.654313
Proc. SPIE 6142, 3D cryo-section/imaging of blood vessel lesions for validation of MRI data, 614214 (2 March 2006); doi: 10.1117/12.649093
Proc. SPIE 6142, Performance of different reflectance and diffuse optical imaging tomographic approaches in fluorescence molecular imaging of small animals, 614215 (2 March 2006); doi: 10.1117/12.647494
Proc. SPIE 6142, Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner, 614216 (2 March 2006); doi: 10.1117/12.650970
Proc. SPIE 6142, Rotating slat collimator design for high-energy near-field imaging, 614217 (2 March 2006); doi: 10.1117/12.653929
X-ray Imaging
Proc. SPIE 6142, Regional exposure management with spatial x-ray gating, 614218 (2 March 2006); doi: 10.1117/12.654066
Proc. SPIE 6142, Applying a proposed definition for receptor dose to digital projection images, 614219 (2 March 2006); doi: 10.1117/12.650136
Proc. SPIE 6142, The impact of angular separation on the performance of biplane correlation imaging for lung nodule detection, 61421A (2 March 2006); doi: 10.1117/12.652588
Proc. SPIE 6142, Evaluation of a physical based approach of scattered radiation correction in cone beam CT with an anthropomorphic thorax phantom, 61421B (2 March 2006); doi: 10.1117/12.650089
Proc. SPIE 6142, Scatter correction for cone-beam computed tomography using simulated object models, 61421C (2 March 2006); doi: 10.1117/12.651027
Proc. SPIE 6142, Development of next generation digital flat panel catheterization system: design principles and validation methodology, 61421D (2 March 2006); doi: 10.1117/12.652757
Dual Energy X-ray Imaging
Proc. SPIE 6142, High-performance dual-energy imaging with a flat-panel detector: imaging physics from blackboard to benchtop to bedside, 61421E (2 March 2006); doi: 10.1117/12.658080
Proc. SPIE 6142, The impact of cardiac gating on the detection of coronary calcifications in dual-energy chest radiography: a phantom study, 61421F (2 March 2006); doi: 10.1117/12.653387
Proc. SPIE 6142, Accuracy and precision of dual energy CT imaging for the quantification of tissue fat content, 61421G (2 March 2006); doi: 10.1117/12.654669
Proc. SPIE 6142, Dual-energy imaging using a photon counting detector with electronic spectrum-splitting, 61421H (2 March 2006); doi: 10.1117/12.649799
Proc. SPIE 6142, Multispectral single-scan lung imaging system: initial feasibility, 61421I (2 March 2006); doi: 10.1117/12.652405
Computational Simulation
Proc. SPIE 6142, Simulated and experimental technique optimization of dual-energy radiography: abdominal imaging applications, 61421J (2 March 2006); doi: 10.1117/12.654001
Proc. SPIE 6142, Light transport in trabecular bone: Monte Carlo simulation based on 3D triangle meshes, 61421K (2 March 2006); doi: 10.1117/12.652237
Proc. SPIE 6142, Optimal spectra for indirect detector breast tomosynthesis, 61421L (2 March 2006); doi: 10.1117/12.649547