24 March 1982 Soft X-Ray Sources For The Max-Planck-Institut (MPI) Long Beam (130 M) Test Facility
Author Affiliations +
Proceedings Volume 0316, High Resolution Soft X-Ray Optics; (1982) https://doi.org/10.1117/12.933155
Event: 1981 Brookhaven Conferences, 1981, Upton, United States
Abstract
At present, a large imaging X-ray telescope with 80 cm aperture is being built in Germany. In order to support this program a 130m long X-ray test facility has been set up, which is successful in operation for about one year. One of its essential components are the focussing X-ray sours which have been developed by us with the following characteristics: flux density of 1013 counts sec-1 ster-1 at 1.5 keV, spatial uniformity of about 5%, temporal stability of 3% over 5 hours.
© (1982) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K. H. Stephan, K. H. Stephan, P. Predehl, P. Predehl, B. Aschenbach, B. Aschenbach, H. Brauninger, H. Brauninger, A. Ondrusch, A. Ondrusch, } "Soft X-Ray Sources For The Max-Planck-Institut (MPI) Long Beam (130 M) Test Facility", Proc. SPIE 0316, High Resolution Soft X-Ray Optics, (24 March 1982); doi: 10.1117/12.933155; https://doi.org/10.1117/12.933155