Paper
21 April 1986 Investigation Of A Compact Laser System For The Frequency Range 300 - 3000 GHz
R. Densing, P. B. Van der Wal, D. Galleguillos, H. P. Roser, R. Wattenbach
Author Affiliations +
Proceedings Volume 0598, Instrumentation for Submillimeter Spectroscopy; (1986) https://doi.org/10.1117/12.952323
Event: 1985 International Technical Symposium/Europe, 1985, Cannes, France
Abstract
A submm laser system, consisting of a CO2 pump, laser and a subs resonator has been developed and applied as a local oscillator in a heterodyne receiver for astronomical air-borne observations. Both lasers can be operated in the "sealed off" mode. The whole laser system, stands out for good mechanical stability and structural compactness.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. Densing, P. B. Van der Wal, D. Galleguillos, H. P. Roser, and R. Wattenbach "Investigation Of A Compact Laser System For The Frequency Range 300 - 3000 GHz", Proc. SPIE 0598, Instrumentation for Submillimeter Spectroscopy, (21 April 1986); https://doi.org/10.1117/12.952323
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Carbon dioxide lasers

Gas lasers

Laser systems engineering

Resonators

Laser resonators

Heterodyning

Receivers

Back to Top