Paper
8 December 1986 High Intensity Soft Flash X-Ray Generator with Two Types of Tubes for Biomedical Use
Hiroshi Isobe, Eiichi Sato, Toru Yanagisawa, Fumihiko Hoshino
Author Affiliations +
Abstract
The construction of a low impedance and high intensity flash x-ray (FX) generator for biomedical radiography is described. This generator consisted of the following components: a high voltage power supply, a low impedance transmission line with a high voltage coaxial condenser (120kV-0.15μF), a compressed-gas (SF6) gap switch with a small-sized trigger device operated by light through a fiber, a trigger delay device, a vacuum pump system, and two evacuated FX tubes, each of a different type, with eight coaxial cables. The FX generator may be used for condenser charging voltage of 50 to 120kV. The electric pulse width of the FX output varied according to the beam quality, anode-cathode (A-C) space, and others, and ranged from 0.1 to 0.4μs. The original FX intensity from the source was determined by the condenser charging voltage and A-C space, and the maximum intensities of the Type A and B tubes were about 100 and 200mR at lm/pulse, respectively. The FX quality was determined by the average voltage of FX tubes, the efficiency of electron beam conversion into FX due to the configuration between the anode and cathode electrodes, and the insertion of metal filters. The effective focal spot varied due primarily to the configuration of electrodes and the insertion of filters. Various clear FX images achieved with a digital radiography system were obtained by controlling the FX intensity, the quality, and the size of the effective focal spot.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hiroshi Isobe, Eiichi Sato, Toru Yanagisawa, and Fumihiko Hoshino "High Intensity Soft Flash X-Ray Generator with Two Types of Tubes for Biomedical Use", Proc. SPIE 0693, High Speed Photography, Videography, and Photonics IV, (8 December 1986); https://doi.org/10.1117/12.936718
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electrodes

Aluminum

Virtual colonoscopy

Radiography

Biomedical optics

Photonics

High speed photography

RELATED CONTENT

Biomedical Flash Radiography
Proceedings of SPIE (February 04 1988)
Flash Energy Subtraction Technique Using a Thin Metal Filter
Proceedings of SPIE (December 08 1986)
A Flash Radiographic System For Biomedical Use
Proceedings of SPIE (June 07 1989)
An Oil-Cooled Flash X-Ray Tube For Biomedical Radiography
Proceedings of SPIE (February 01 1989)

Back to Top