1 January 1986 Analytical Model For Transient Strehl Ratio Distribution In Soft X-Ray Optical Systems
Author Affiliations +
Proceedings Volume 0733, Soft X-Ray Optics and Technology; (1986) https://doi.org/10.1117/12.964908
Event: Soft X-Ray Optics and Technology, 1987, Berlin, Germany
Abstract
This paper will describe a first order analytical technique for evaluating the Strehl ratio of a system composed of various optical components in a soft x-ray system. The basic elements of the model are to provide budgeting criteria that will permit the maximum energy in the central lobe of a far field distribution. Budgeting components will consist of figure error on the component, thermal distortion for transient and steady-state, pressure ripple for cooled substrates, and energy loss due to scatter and absorption in the coatings and the substrate.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J. R. Palmer, J. R. Palmer, } "Analytical Model For Transient Strehl Ratio Distribution In Soft X-Ray Optical Systems", Proc. SPIE 0733, Soft X-Ray Optics and Technology, (1 January 1986); doi: 10.1117/12.964908; https://doi.org/10.1117/12.964908