Abstract
Infrared fiber optic pyrometry has become a practical reality using improved strength fluoride glass fibers. The addition of a plastic coating and rugged cabling allows the fibers to be used in the field. A detailed theoretical model of the infrared fiber optic pyrometer (non-contact or radiative thermometer) has been derived and compared with data produced by a prototype fluoride glass fiber radiative thermometer. Excellent agreement was obtained between theory and experiment over a temperature range of 30 to 700° C.
© (1987) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. C. Tran, K. H. Levin, R. Mossadegh, and Steve Koontz "IR Fiber Temperature Sensing System", Proc. SPIE 0843, Infrared Optical Materials and Fibers V, (1 January 1987); https://doi.org/10.1117/12.968228