Using lasers for therapeutic applications is getting more and more accepted. In ophthalmology Ar-lasers for intraocular applications are quite common. The Nd:YAG-laser is used as a high power tool in connection with silica fibers for different extracorporal and intracorporal applications. The CO2-laser is the cutting laser, one problem being the beam transmission: The state of the art in fibers is not sufficient up to now. Because of the high power used safety against laser radiation hazard is of great importance. The safety in laser use is primarily dependent on the surgeons cautiousness, e.g. using laser protection goggels, observing that the spot of the aiming beam is present etc. On the other hand the laser and fiber system has to be inherently safe by appropriate technical means as far as possible. An additional aspect adding to safety is the handling: With easier system handling less attention of the surgeon is necessary for driving the apparatus. Thus he can concentrate on the patient and on the procedure. In considering the fiber system one important point in handling and safety is the coupling of the fiber to the laser head. The development philosophy in this coupling may be divided into two groups: - one is trying to use standard connectors which were initially developed for data transmission; - the other is using special connectors. One example of the first group is the guiding of the laser beam from the Ar-laser to the slit-lamp in ophtalmology. Here the well-known F-SMA connectors together with a special fiber with adapted numerical aperture are used. The advantage of such a system is the low price of the connector. For high power lasers such as the clinical Nd:YAG lasers with 40 to 150 W those connectors are not suitable. Up to now every laser manufacturer developed his own connector system in this field.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K.-H. Schonborn and W. Wodrich "Handling And Safety Aspects Of Fiber Optic Laser Beam Delivery Systems", Proc. SPIE 0906, Optical Fibers in Medicine III, (21 June 1988); https://doi.org/10.1117/12.945287
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fiber lasers

Connectors

Safety

Laser safety

Surgery

Laser systems engineering

Laser therapeutics

RELATED CONTENT

High power fiber lasers in geothermal, oil and gas
Proceedings of SPIE (March 12 2014)
Mobile laser cutting system for complex rescue operations
Proceedings of SPIE (February 15 2018)
Optical Fibers With Enlarged Ends For Surgical Use
Proceedings of SPIE (March 26 1984)
Recent Developments Of The Laser In Medicine
Proceedings of SPIE (March 01 1974)
Perspectives of powerful laser technique for medicine
Proceedings of SPIE (November 01 1991)

Back to Top