Paper
14 June 1988 Design Consideration Of A Radiation Cooled Slotted Rotating Target X-Ray Source
S Hattori, M Asano, T Tagawa, S Yoshikawa
Author Affiliations +
Abstract
A practical design of 0.1 cm diameter, 10 KW e-beam power, point x-ray source with v-shaped slotted rotating target is discussed. This point x-ray source can give penumbra--2 intra-wafer-distortion trade-off resolution of 0.13 pm and inverse-throughput for 25cm-2 sensitivity resist of 1.8 s•cm-1. Temporal temperature rise for 7 cm slot radius and 50 s-1 revolution remain within 260 °C. Effect of radiation cooling by stacked fins are calculated. Thus estimate average temperature rise amounts to 490°C over cooling temperature. Estimated temperature rise of rotating axis is 300 °C. Effect of stacked fins as evacuation resistance is also discussed. We can maintain e-beam chamber within 10-8 torr by using fero-fluidic seal working at 10-8 torr condition.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S Hattori, M Asano, T Tagawa, and S Yoshikawa "Design Consideration Of A Radiation Cooled Slotted Rotating Target X-Ray Source", Proc. SPIE 0923, Electron-Beam, X-Ray, and Ion Beam Technology: Submicrometer Lithographies VII, (14 June 1988); https://doi.org/10.1117/12.945647
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lithography

X-ray technology

X-ray sources

Radiation effects

X-ray lithography

Aluminum

X-rays

Back to Top