29 January 1989 Attenuation Screens In Interferometer Cavities
Author Affiliations +
Abstract
Attenuation screens of different types are used frequently in interferometer cavities when one wishes to control the intensity of one arm with respect to another arm, to achieve good fringe contrast. A study of attenuation screens for use in interferometer cavities was performed to determine the optimum attenuation screen mesh frequency, orientation, and cavity location, theoretically and experimentally. A commercially avaliable Fizeau type interferometer was used for the investigations. Screen frequencies of 500, 400, 325, 230, and 100 wires per inch were used. Experimental results with these screens of different test configurations are presented. The durable, inexpensive, and versatile attenuation screen provides an excellent alternative to coated or metallized pellicles used as attenuation filters.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael Pate, Michael Pate, Murty V Mantravadi, Murty V Mantravadi, } "Attenuation Screens In Interferometer Cavities", Proc. SPIE 0966, Advances in Fabrication and Metrology for Optics and Large Optics, (29 January 1989); doi: 10.1117/12.948070; https://doi.org/10.1117/12.948070
PROCEEDINGS
8 PAGES


SHARE
Back to Top