31 October 2016 Er-doped fiber based Mach-Zehnder interferometer for simultaneous strain and temperature measurement
Author Affiliations +
Abstract
A novel mode interferometer for simultaneous strain and temperature measurement is proposed, which is based on Mach-Zehnder interferometer (MZI) realized by splicing a short section Er-Doped fiber (EDF) between two sections of single mode fibers (SMF) with core-offset technique. The structure is compact and easy to fabricate. A strain sensitivity of 0.0247 dB/με and a temperature sensitivity of 0.2225dB/℃are achieved experimentally.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Na Zhang, Na Zhang, Wei Xu, Wei Xu, Cheungchuen Yu, Cheungchuen Yu, Changyuan Yu, Changyuan Yu, Shanhong You, Shanhong You, } "Er-doped fiber based Mach-Zehnder interferometer for simultaneous strain and temperature measurement", Proc. SPIE 10019, Optoelectronic Devices and Integration VI, 100190L (31 October 2016); doi: 10.1117/12.2263344; https://doi.org/10.1117/12.2263344