Presentation
2 May 2017 Reducing user error in dipstick urinalysis with a low-cost slipping manifold and mobile phone platform (Conference Presentation)
Gennifer T. Smith, Nicholas Dwork, Saara A. Khan, Matthew Millet, Kiran Magar, Mehdi Javanmard, Audrey K. Bowden
Author Affiliations +
Abstract
Urinalysis dipsticks were designed to revolutionize urine-based medical diagnosis. They are cheap, extremely portable, and have multiple assays patterned on a single platform. They were also meant to be incredibly easy to use. Unfortunately, there are many aspects in both the preparation and the analysis of the dipsticks that are plagued by user error. This high error is one reason that dipsticks have failed to flourish in both the at-home market and in low-resource settings. Sources of error include: inaccurate volume deposition, varying lighting conditions, inconsistent timing measurements, and misinterpreted color comparisons. We introduce a novel manifold and companion software for dipstick urinalysis that eliminates the aforementioned error sources. A micro-volume slipping manifold ensures precise sample delivery, an opaque acrylic box guarantees consistent lighting conditions, a simple sticker-based timing mechanism maintains accurate timing, and custom software that processes video data captured by a mobile phone ensures proper color comparisons. We show that the results obtained with the proposed device are as accurate and consistent as a properly executed dip-and-wipe method, the industry gold-standard, suggesting the potential for this strategy to enable confident urinalysis testing. Furthermore, the proposed all-acrylic slipping manifold is reusable and low in cost, making it a potential solution for at-home users and low-resource settings.
Conference Presentation
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gennifer T. Smith, Nicholas Dwork, Saara A. Khan, Matthew Millet, Kiran Magar, Mehdi Javanmard, and Audrey K. Bowden "Reducing user error in dipstick urinalysis with a low-cost slipping manifold and mobile phone platform (Conference Presentation)", Proc. SPIE 10081, Frontiers in Biological Detection: From Nanosensors to Systems IX, 100810J (2 May 2017); https://doi.org/10.1117/12.2256593
Advertisement
Advertisement
KEYWORDS
Cell phones

Error analysis

Light sources and illumination

Video processing

Biological detection systems

Data processing

Medical diagnostics

Back to Top