9 March 2017 Comparison of high resolution x-ray detectors with conventional FPDs using experimental MTFs and apodized aperture pixel design for reduced aliasing
Author Affiliations +
Abstract
Apodized Aperture Pixel (AAP) design, proposed by Ismailova et.al, is an alternative to the conventional pixel design. The advantages of AAP processing with a sinc filter in comparison with using other filters include non-degradation of MTF values and elimination of signal and noise aliasing, resulting in an increased performance at higher frequencies, approaching the Nyquist frequency. If high resolution small field-of-view (FOV) detectors with small pixels used during critical stages of Endovascular Image Guided Interventions (EIGIs) could also be extended to cover a full field-of-view typical of flat panel detectors (FPDs) and made to have larger effective pixels, then methods must be used to preserve the MTF over the frequency range up to the Nyquist frequency of the FPD while minimizing aliasing. In this work, we convolve the experimentally measured MTFs of an Microangiographic Fluoroscope (MAF) detector, (the MAF-CCD with 35μm pixels) and a High Resolution Fluoroscope (HRF) detector (HRF-CMOS50 with 49.5μm pixels) with the AAP filter and show the superiority of the results compared to MTFs resulting from moving average pixel binning and to the MTF of a standard FPD. The effect of using AAP is also shown in the spatial domain, when used to image an infinitely small point object. For detectors in neurovascular interventions, where high resolution is the priority during critical parts of the intervention, but full FOV with larger pixels are needed during less critical parts, AAP design provides an alternative to simple pixel binning while effectively eliminating signal and noise aliasing yet allowing the small FOV high resolution imaging to be maintained during critical parts of the EIGI.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Shankar, A. Shankar, M. Russ, M. Russ, S. Vijayan, S. Vijayan, D. R. Bednarek, D. R. Bednarek, S. Rudin, S. Rudin, } "Comparison of high resolution x-ray detectors with conventional FPDs using experimental MTFs and apodized aperture pixel design for reduced aliasing", Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging, 101323Z (9 March 2017); doi: 10.1117/12.2254402; https://doi.org/10.1117/12.2254402
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

DQE simulation of a-Se x-ray detectors using ARTEMIS
Proceedings of SPIE (March 22 2016)
Design Method For Ultra-High Resolution Linear CCD Imagers
Proceedings of SPIE (November 08 1984)
Aliasing phenomenon in EBCCD imaging
Proceedings of SPIE (August 30 2002)
Image processing in neutron penumbral imaging
Proceedings of SPIE (August 22 1995)
System Design Considerations Of CCD Based Line Imagers
Proceedings of SPIE (August 24 1988)

Back to Top