3 March 2017 Fully automated calculation of cardiothoracic ratio in digital chest radiographs
Author Affiliations +
Abstract
The calculation of Cardiothoracic Ratio (CTR) in digital chest radiographs would be useful for cardiac anomaly assessment and heart enlargement related disease indication. The purpose of this study was to develop and evaluate a fully automated scheme for calculation of CTR in digital chest radiographs. Our automated method consisted of three steps, i.e., lung region localization, lung segmentation, and CTR calculation. We manually annotated the lung boundary with 84 points in 100 digital chest radiographs, and calculated an average lung model for the subsequent work. Firstly, in order to localize the lung region, generalized Hough transform was employed to identify the upper, lower, and outer boundaries of lung by use of Sobel gradient information. The average lung model was aligned to the localized lung region to obtain the initial lung outline. Secondly, we separately applied dynamic programming method to detect the upper, lower, outer and inner boundaries of lungs, and then linked the four boundaries to segment the lungs. Based on the identified outer boundaries of left lung and right lung, we corrected the center and the declination of the original radiography. Finally, CTR was calculated as a ratio of the transverse diameter of the heart to the internal diameter of the chest, based on the segmented lungs. The preliminary results on 106 digital chest radiographs showed that the proposed method could obtain accurate segmentation of lung based on subjective observation, and achieved sensitivity of 88.9% (40 of 45 abnormalities), and specificity of 100% (i.e. 61 of 61 normal) for the identification of heart enlargements.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lin Cong, Luan Jiang, Gang Chen, Qiang Li, "Fully automated calculation of cardiothoracic ratio in digital chest radiographs", Proc. SPIE 10134, Medical Imaging 2017: Computer-Aided Diagnosis, 1013432 (3 March 2017); doi: 10.1117/12.2254398; https://doi.org/10.1117/12.2254398
PROCEEDINGS
6 PAGES


SHARE
RELATED CONTENT

Normalization of chest radiographs
Proceedings of SPIE (February 28 2013)
Segmentation of ribs in digital chest radiographs
Proceedings of SPIE (March 29 2016)
Interactive shape models
Proceedings of SPIE (May 15 2003)
Improved Lung Nodule Detection With An Equalized Image
Proceedings of SPIE (August 18 1980)

Back to Top