Presentation + Paper
16 May 2017 Response time improvement of LWIR HOT MCT detectors
Author Affiliations +
Abstract
Theoretical and experimental investigations on the response time improvement of biased and unbiased long-wave infrared (LWIR) HgCdTe detectors operating at temperatures T = 230K were presented in this paper. MOCVD technology is an excellent tool in fabrication of different HgCdTe detector structures with a wide range of composition, donor/acceptor doping and without post grown ex-situ annealing. Donor doping efficiency in (111) and (100) oriented HgCdTe layers has been discussed. The time constant is lower in biased detectors due to Auger suppression phenomena and reduction of diffusion capacitance related to wider depletion region. The relatively high bias currents requirements and excessive low frequency noise which reduces the detectivity of biased detectors inspire researches on the time constant improvement of unbiased detectors. The response time of high-operating temperature (HOT) LWIR HgCdTe detectors revealed complex behavior being dependent on the applied the reverse bias, the operating temperature, the absorber thickness and doping, the series resistance and the electrical area of the devices.
Conference Presentation
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
P. Madejczyk, W. Gawron, A. Kębłowski, P. Martyniuk, M. Kopytko, W. Pusz, D. Stępień, J. Rutkowski, A. Piotrowski, J. Piotrowski, and A. Rogalski "Response time improvement of LWIR HOT MCT detectors", Proc. SPIE 10177, Infrared Technology and Applications XLIII, 1017719 (16 May 2017); https://doi.org/10.1117/12.2261786
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Long wavelength infrared

Mercury cadmium telluride

Doping

Annealing

Diffusion

Infrared detectors

RELATED CONTENT

Low dark current p on n MCT detector in long...
Proceedings of SPIE (June 11 2015)
Heterostructure HgCdTe photovoltaic detectors
Proceedings of SPIE (February 22 2001)
Non-cryogenic operation of HgCdTe infrared detectors
Proceedings of SPIE (January 22 2010)

Back to Top