Translator Disclaimer
Paper
26 April 1989 Generalized Self-Filtering Unstable Resonators Applied To XeCl Lasers
Author Affiliations +
Proceedings Volume 1023, Excimer Lasers and Applications; (1989) https://doi.org/10.1117/12.950139
Event: 1988 International Congress on Optical Science and Engineering, 1988, Hamburg, Germany
Abstract
We present the results of a detailed experimental study of the operation of two Gen-eralized Self-Filtering Unstable Resonators applied respectively to two different UV-preionized excimer lasers. By applying a G-SFUR with magnification |M|=10 to a short pulse XeC1 laser, a diffraction limited laser beam of 3.5 mJ, 11 ns duration and with a brightness of 4.8 x 1013 W cm-2 Sr-1 has been obtained. With a G-SFUR having |M|=20 applied to a longer pulse XeCl laser a diffraction limited beam of 21 mJ, 18 ns duration and with a brightness of 2.1 x 1014 W cm-2 Sr-1 has been obtained. The effect of the filtering aperture dimension on the output beam energy and divergence has been also investigated.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
V. Nassisi and M. R. Perrone "Generalized Self-Filtering Unstable Resonators Applied To XeCl Lasers", Proc. SPIE 1023, Excimer Lasers and Applications, (26 April 1989); https://doi.org/10.1117/12.950139
PROCEEDINGS
10 PAGES


SHARE
Advertisement
Advertisement
RELATED CONTENT

Short pulse KrF laser with M2 reduction by a super...
Proceedings of SPIE (May 24 1999)
Filtering resonators copper vapor laser
Proceedings of SPIE (March 23 2005)
Three-dimensional excimer laser cavity model
Proceedings of SPIE (June 01 1990)

Back to Top