21 June 2017 Micro-X-ray fluorescence spectrometer with x-ray single bounce metallic capillary optics for light element analysis (Conference Presentation)
Robert Mroczka, Grzegorz Żukociński, Rafał Łopucki
Author Affiliations +
Abstract
In the last 20 years, , due to the rapid development of X-ray optics, micro X-ray fluorescence spectrometry (micro-XRF) has become a powerful tool to determine the spatial distribution of major, minor, and trace elements within a sample. Micro-X-ray fluorescence (micro-XRF) spectrometers for light element analysis (6 ≤ Z ≤ 14) using glass polycapillary optics are usually designed and applied to confocal geometry. Two such X-ray optics systems are used in this setup. The first one focuses the primary beam on the sample; the second restricts the field of view of the detector. In order to be able to analyze a wider range of elements especialy with (6 ≤ Z ≤ 14), both sample and detector are under vacuum. Depth resolution varies between 100 μm at 1 keV fluorescence energy (Na-Kα) and 30 μm for 17.5 keV (Mo-Kα) [1,2].

In order to improve resolution at energies below 9 keV, our group designed similar spectrometer (in cooperation with PREVAC) but instead of primary polycapillary optics we applied single bounce metallic capillaries optics , designed and manufactured in our Laboratory. The vacuum chumber is currently under construction and is expected to be fully operational in September this year. Single bounce gold capillaries with elliptic internal shape have recently been redesigned and developed in our Laboratory. Surface roughness was reduced up to 0.5 nm and slope error to 0.3 mrad. For these capillaries an expected depth resolution varies from 3 μm (1 keV) and 10 µm for 9 keV (Cu-Kα). The spectrometer equipped with gold capillaries offers the possibility of elemental analysis with better depth resolution than is offerred by glass polycapillaries at energies below 9 keV. Furthermore, we will compare the capabilities and limitations of this spectrometer with others, that use laboratory and/or synchrotron sources.

Acknowledgments: This work was supported and co-funded by the European Union as part of the Operational Programme Development of Eastern Poland for 2007–2013, Priority I Innovative Economy, Measure I.3. Support for Innovations and The National Centre for Research and Development, Project no. TANGO1,267102/NCBR/2015
Conference Presentation
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert Mroczka, Grzegorz Żukociński, and Rafał Łopucki "Micro-X-ray fluorescence spectrometer with x-ray single bounce metallic capillary optics for light element analysis (Conference Presentation)", Proc. SPIE 10235, EUV and X-ray Optics: Synergy between Laboratory and Space V, 102350E (21 June 2017); https://doi.org/10.1117/12.2267636
Advertisement
Advertisement
KEYWORDS
Spectroscopy

Capillaries

X-ray optics

Fluorescence spectroscopy

Optical components

Luminescence

Optics manufacturing

RELATED CONTENT

Elemental analysis with x-ray fluorescence spectrometry
Proceedings of SPIE (December 11 2012)
X-ray fluorescent spectrometer Focus M
Proceedings of SPIE (July 30 2002)
Use of Kumakhov optics for x-ray analysis
Proceedings of SPIE (July 19 1996)
Achievements of capillary technology
Proceedings of SPIE (December 06 2006)

Back to Top