Abstract
By use of extended finite element analysis method, a calculation of J-integral for interface crack on Micro-arc Oxidation(MAO) ceramic coating on aluminum alloy was conducted. The feasibility of using J-integral as a fracture parameter to characterize the interfacial fracture toughness is discussed. The relation between J-integral and length of interface crack, thickness of ceramic coating is studied. Analysis result indicates that with the expansion of the interface crack length, resistance bi-material interface enhancements, and interfacial fracture toughness enhances, the J-integral increases with the increase of crack length. When the thickness of the ceramic coating is upon 40μm-100μm, interfacial fracture toughness is better. J-integral value shows a decreasing trend with the increase of the thickness of the ceramic coating.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Cheng Gao, Huiyu Tao, Dayong Cai, Jinyong Xu, Yan Tang, Ranran Huang, "J-integral for interface crack on micro-arc oxidation ceramic coating", Proc. SPIE 10322, Seventh International Conference on Electronics and Information Engineering, 1032238 (23 January 2017); doi: 10.1117/12.2265237; https://doi.org/10.1117/12.2265237