23 August 2017 Soft x-ray grating compressors for free-electron-laser pulses
Author Affiliations +
Abstract
We discuss the design of double plane grating compressors to be used for chirped pulse amplification on free-electron laser (FEL) ultrashort pulses at energies higher than 100 eV. In particular, the design of a grating compressor for wavelength emission centered at 10 nm is demonstrated. The XUV efficiency measurements in the 8-12 nm range of the gratings to be used in a double plane grating compressor realized for an upcoming experiment planned at FERMI is presented and discussed. The overall instrument efficiency is furthermore analyzed.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paolo Miotti, Paolo Miotti, Nicola Fabris, Nicola Fabris, Fabio Frassetto, Fabio Frassetto, Stefano Turchini, Stefano Turchini, Paola Zuppella, Paola Zuppella, Luca Poletto, Luca Poletto, } "Soft x-ray grating compressors for free-electron-laser pulses", Proc. SPIE 10386, Advances in X-Ray/EUV Optics and Components XII, 103860R (23 August 2017); doi: 10.1117/12.2275031; https://doi.org/10.1117/12.2275031