30 October 2017 Diffractive optics for precision alignment of Euclid space telescope optics
Author Affiliations +
Abstract
We present a method for precise alignment of lens elements using specific Computer Generated Hologram (CGH) with an integrated Fizeau reference flat surface and a Fizeau interferometer. The method is used for aligning the so called Camera Lens Assembly for ESAs Euclid telescope. Each lens has a corresponding annular area on the diffractive optics, which is used to control the position of each lens. The lenses are subsequently positioned using individual annular rings of the CGH. The overall alignment accuracy is below 1 µm, the alignment sensitivity is in the range of 0.1 µm. The achieved alignment accuracy of the lenses relative to each other is mainly depending on the stability in time of the alignment tower. Error budgets when using computer generated holograms and physical limitations are explained. Calibration measurements of the alignment system and the typically reached alignment accuracies will be shown and discussed.
Conference Presentation
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jean-Michel Asfour, Frank Weidner, Christof Bodendorf, Andreas Bode, Alexander G. Poleshchuk, Ruslan K. Nasyrov, Frank Grupp, Ralf Bender, "Diffractive optics for precision alignment of Euclid space telescope optics", Proc. SPIE 10401, Astronomical Optics: Design, Manufacture, and Test of Space and Ground Systems, 104010V (30 October 2017); doi: 10.1117/12.2274349; https://doi.org/10.1117/12.2274349
PROCEEDINGS
12 PAGES + PRESENTATION

SHARE
RELATED CONTENT

Realization of the MIDI cold optics
Proceedings of SPIE (February 21 2003)
Calibration database for the Hubble Space Telescope
Proceedings of SPIE (November 01 1993)
High-precision testing of optical components
Proceedings of SPIE (September 21 1998)