5 March 2018 The design of Nb5N6 microbolometer detector for 0.3 THz detector
Author Affiliations +
Abstract
We design and simulate planar antenna structure on the high- resistivity silicon substrate(ρ=1000Ω·cm) for the Nb5N6 micro- bolometer at the frequency range from 0.265 THz to 0.365 THz by CST Studio Suite. We have obtained the center frequency of the antenna at 0.3 THz by optimizing parameters of the antenna structure and the antenna has the very good radiation directivity. And the maximum directivity of the antenna is around 8.634 dBi at 0.3THz. The measured best voltage response of the Nb5N6 micro-bolometer detector is at 0.307 THz. The measured response frequency and the simulated S-parameter are in substantial agreement.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chengtao Jiang, Chengtao Jiang, Xuecou Tu, Xuecou Tu, Peng Xiao, Peng Xiao, Shimin Zhai, Shimin Zhai, Xiaoqing Jia, Xiaoqing Jia, Lin Kang, Lin Kang, Jian Chen, Jian Chen, Peiheng Wu, Peiheng Wu, } "The design of Nb5N6 microbolometer detector for 0.3 THz detector", Proc. SPIE 10531, Terahertz, RF, Millimeter, and Submillimeter-Wave Technology and Applications XI, 1053123 (5 March 2018); doi: 10.1117/12.2292539; https://doi.org/10.1117/12.2292539