9 March 2018 Determination of the limit of detection for iodinated contrast agents with multi-energy computed tomography
Megan C. Jacobsen, Xinhui Duan, Dianna D. Cody, Erik Cressman, Dawid Schellingerhout, Rick R. Layman
Author Affiliations +
Abstract
Multiple studies in the literature have proposed diagnostic thresholds based on Multi-Energy Computed Tomography (MECT) iodine maps. However, it is critical to determine the minimum detectable iodine concentration for MECT systems to assure the clinical accuracy for various measured concentrations for these image types. In this study, seven serial dilutions of iohexol were made with concentrations from 0.03 to 2.0 mg Iodine/mL in 50 mL centrifuge tubes. The dilutions and one blank vial were scanned five times each in two scatter conditions: within a 20.0 cm diameter (Head) phantom, and a 30.0 cm x 40.0 cm elliptical (Body) phantom. This was repeated on a total of six scanners from three vendors: fast-kVp switching, dual-source dual-energy CT, dual-layer detector CT, and split-filter CT. Scan parameters and dose were matched as closely as possible across systems, and iodine maps were reconstructed. Regions-of-Interest (ROIs) were placed on 5 consecutive images within each vial, for a total of 25 measurements per sample. The mean and standard deviation were calculated for each sample. The Limit of Detection (LOD) was defined as the concentration that had a 95% chance of having a signal above the 95% confidence interval of the measured blank samples. The range of LODs was 0.021 – 0.484 mg I/mL in the head phantom and 0.125 – 0.547 mg I/mL in the body phantom. The LOD for iodinated contrast using MECT systems changed with scatter and attenuation conditions. The limit of detection for all conditions was under 0.5 mg Iodine/mL.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Megan C. Jacobsen, Xinhui Duan, Dianna D. Cody, Erik Cressman, Dawid Schellingerhout, and Rick R. Layman "Determination of the limit of detection for iodinated contrast agents with multi-energy computed tomography", Proc. SPIE 10573, Medical Imaging 2018: Physics of Medical Imaging, 105734Q (9 March 2018); https://doi.org/10.1117/12.2293935
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computed tomography

Iodine

Scanners

Dual energy imaging

Quantitative analysis

Back to Top