You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
24 May 2018Resolution limits of terahertz ptychography
We present a study on the resolution limits and resolution factors of terahertz (THz) ptychography. Simulations of a binary amplitude object show that ptychography shares the same intrinsic resolution factors with digital holography, i.e. it is diffraction-limited. Reconstructions of amplitude and phase objects obtained from holographic and ptychographic experiments are comparable. A lateral resolution of around one wavelength λ is achieved on an amplitude object, while a depth resolution of around λ/5 is reported on a weakly diffracting phase object. THz ptychography is expected to complement THz holography for imaging biological samples and THz transparent specimens.