Paper
17 May 2018 Photonic immobilization techniques used for the detection of cardiovascular disease biomarkers
Odete Gonçalves, María-José Bañuls, Rafael Alonso, Pilar Jiménez-Meneses, Ángel Maquieira, Henrik Vorum M.D., Steffen B. Petersen, Maria Teresa Neves-Petersen
Author Affiliations +
Abstract
In today’s point-of-care testing (POCT), there is an ever-increasing demand for novel and more efficient devices for early diagnosis, especially in cardiovascular diseases (CVD). Early detection of CVD markers, such as Troponin present in the bloodstream, is a key factor for reducing CVD mortality rates.

Thiol-ene coupling (TEC) and Light Assisted Molecular Immobilization (LAMI) are photonic techniques leading to immobilization of bioreceptors, such as, antibodies which recognize cardiac markers. These techniques present advantages compared to traditional immobilization techniques since, e.g., there are no thermal or chemical steps and they work in water media. TEC reaction takes place at close-to-visible wavelengths (λ=365nm) which induces the formation of thiol radicals which bind to alkene functional group on the surface through a thioether bond. LAMI secures molecular immobilizations in a spatially oriented, localized and covalent coupling of biomolecules onto thiol reactive surfaces down to submicrometer spatial resolution. LAMI is possible due to a conserved structural motif in proteins: the spatial proximity between aromatic residues and disulfide bridges. When aromatic residues are excited with UV light (275- 295nm), disulphide bridges are disrupted and free thiol groups are formed that can bind covalently to a surface decorated with thiol groups.

We have achieved successful immobilization of anti-troponin and anti-myoglobin antibodies with both photonic immobilization techniques. The microarrays of immobilized monoclonal antibodies have successfully detected the CVD biomarkers troponin I and myoglobin, as confirmed by fluorescence imaging. A sandwich immunoassay was carried out, Troponin I and Myoglobin were detected down to 10 ng/mL and 1 ng/mL, respectively.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Odete Gonçalves, María-José Bañuls, Rafael Alonso, Pilar Jiménez-Meneses, Ángel Maquieira, Henrik Vorum M.D., Steffen B. Petersen, and Maria Teresa Neves-Petersen "Photonic immobilization techniques used for the detection of cardiovascular disease biomarkers", Proc. SPIE 10685, Biophotonics: Photonic Solutions for Better Health Care VI, 106852Z (17 May 2018); https://doi.org/10.1117/12.2305717
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Biosensors

Proteins

Ultraviolet radiation

Bridges

Visualization

Monoclonal antibodies

Chemistry

Back to Top