Paper
6 July 2018 The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering
Valentina Fioretti, Andrea Bulgarelli, Simone Lotti, Claudio Macculi, Teresa Mineo, Luigi Piro, Debora Bruno, Massimo Cappi, Mauro Dadina
Author Affiliations +
Abstract
Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is needed to evaluate the impact of low energy protons scattering on the ATHENA mirror surface and the induced residual background level on its X-ray detectors. The Geant4 mass model of ATHENA SPO is built as part of the ESA AREMBES project activities using the BoGEMMS framework. An SPO mirror module row is the atomic unit of the mass model, allowing the simulation of the full structure by means of 20 independent runs, one for each row. No reflecting coating is applied in the model: this simplification implies small differences (few percentages) in the proton flux, while reducing the number of volumes composing the mass model and the consequent simulation processing time. Thanks to the BoGEMMS configuration files, both single pores, mirror modules or the entire SPO row can be built with the same Geant4 geometry. The conical approximation used for the Si plates transmits 20% less photons than the actual SPO design, simulated with a ray-tracing code. Assuming the same transmission reduction for protons, a 20% uncertainty can be accepted given the overall uncertainties of the input fluxes. Both Remizovich, in its elastic approximation, and Coulomb single scattering Geant4 models are used in the interaction of mono-energetic proton beams with a single SPO pore. The scattering efficiency for the first model is almost twice the efficiency obtained with the latter but for both cases we obtain similar polar and azimuthal angular distributions, with about 70-75% of scatterings generated by single or double reflections. The soft proton flux modelled for the plasma sheet region is used as input for the simulation of soft proton funneling by the full SPO mass model. A much weaker soft proton vignetting than the one observed by XMM-Newton EPIC detectors is generated by ATHENA mirrors. The residual soft proton flux reaching the focal plane, defined as a 15 cm radius, is 104 times lower than the input L2 soft proton population entering the mirror, at the same energy, with rates comparable or higher than the ones observed in XMM EPIC-pn most intense soft proton flares.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Valentina Fioretti, Andrea Bulgarelli, Simone Lotti, Claudio Macculi, Teresa Mineo, Luigi Piro, Debora Bruno, Massimo Cappi, and Mauro Dadina "The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering", Proc. SPIE 10699, Space Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray, 106993J (6 July 2018); https://doi.org/10.1117/12.2312729
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scattering

Silicon

Mirrors

X-rays

Coating

Physics

Particles

RELATED CONTENT

Aberration-free silicon pore x-ray optics
Proceedings of SPIE (September 26 2013)
A fully analytical treatment of stray light in silicon pore...
Proceedings of SPIE (September 12 2022)
Stray x-ray flux in the Athena Mirror
Proceedings of SPIE (September 09 2019)

Back to Top