Presentation + Paper
10 July 2018 Laboratory integration of the DKIST wavefront correction system
Author Affiliations +
Abstract
The Wavefront Correction (WFC) system for the Daniel K. Inouye Solar Telescope (DKIST) is in its final stages of laboratory integration. All optical, mechanical, and software components have been unit tested and installed and aligned in our laboratory testbed in Boulder, CO. We will verify all aspects of WFC system performance in the laboratory before disassembling and shipping it to Maui for final integration with the DKIST in early 2019. The DKIST Adaptive Optics (AO) system contains a 1600-actuator deformable mirror, a correlating Shack- Hartmann wavefront sensor, a fast tip-tilt mirror, and an FPGA-based control system. Running at a nominal rate of 1975 Hz, the AO system will deliver diffraction-limited images to five of the DKIST science instruments simultaneously. The DKIST AO system is designed to achieve the diffraction limit (on-axis Strehl > 0.3) at wavelengths up to 500 nm in median daytime seeing (r0 = 7 cm). In addition to AO for diffraction-limited observing, the DKIST WFC system has a low-order wavefront sensor for sensing quasi-static wavefront errors, a context viewer for telescope pointing and image quality assessment, and an active optics engine. The active optics engine uses inputs from the low-order wavefront sensor and the AO system to actively correct for telescope misalignment. All routine alignment and calibration procedures are automated via motorized stages that can be controlled from Python scripts. We present the current state of the WFC system as we prepare for final integration with the DKIST, including verification test design, system performance metrics, and laboratory test data.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Luke C. Johnson, Keith Cummings, Mark Drobilek, Erik Johansson, Jose Marino, Rachel Rampy, Kit Richards, Thomas Rimmele, Predrag Sekulic, and Friedrich Wöger "Laboratory integration of the DKIST wavefront correction system", Proc. SPIE 10703, Adaptive Optics Systems VI, 107030F (10 July 2018); https://doi.org/10.1117/12.2314012
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Wavefronts

Wavefront sensors

Telescopes

Adaptive optics

Calibration

Mirrors

Cameras

RELATED CONTENT

Overview of the LSST active optics system
Proceedings of SPIE (August 04 2014)
Adaptive optics for the European very large telescope
Proceedings of SPIE (December 01 1991)
Performance of ChAOS on the Apache Point Observatory's 3.5 m...
Proceedings of SPIE (September 11 1998)
PCR a PC based wave front reconstructor for MMT...
Proceedings of SPIE (July 14 2008)

Back to Top