Presentation + Paper
10 July 2018 The dirt in astronomy's genie lamp: ThO contamination of Th-Ar calibration lamps
Gillian Nave, Florian Kerber, Elizabeth A. Den Hartog, Gaspare Lo Curto
Author Affiliations +
Abstract
Thorium-Argon hollow cathode lamps are commonly used as wavelength calibration lamps for high-resolution astronomical spectrographs (e.g. the European Southern Observatory’s (ESO) High Accuracy Radial velocity Planet Searcher (HARPS) and Ultraviolet and Visual Echelle Spectrograph (UVES)). They have been instrumental in supporting high precision work such as the search for extra-solar planets using the radial-velocity method. However, several years ago astronomers found that the quality of commercial Th-Ar lamps had deteriorated, when new lamps showed a “forest” of lines at low intensity levels obscuring faint atomic thorium lines rendering them useless for wavelength calibration in some regions. Based on information provided by the manufacturers the presence of molecular emission from thorium oxides has been suspected as the likely cause of this problem. We have now conclusively identified the observed emission bands as being due to strong molecular bands of ThO, confirming the source of the contamination of the hollow cathode lamps.

We have recorded spectra of new Th-Ar lamps showing contamination using the high-resolution echelle spectrograph at the University of Wisconsin and ESO’s new Echelle SPectrograph for Rocky Exoplanets and Stable Spectroscopic Observations (ESPRESSO) spectrograph in order to determine the positions of the ThO lines. We shall present our initial analyses of these spectra, describing the wavelength regions most affected, their dependence on the lamp current, and measurements of the ThO line positions.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gillian Nave, Florian Kerber, Elizabeth A. Den Hartog, and Gaspare Lo Curto "The dirt in astronomy's genie lamp: ThO contamination of Th-Ar calibration lamps", Proc. SPIE 10704, Observatory Operations: Strategies, Processes, and Systems VII, 1070407 (10 July 2018); https://doi.org/10.1117/12.2312286
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lamps

Thorium

Calibration

Spectrographs

Astronomy

Argon

Contamination

Back to Top