5 March 2018 A micro-vibration generated method for testing the imaging quality on ground of space remote sensing
Author Affiliations +
Proceedings Volume 10710, Young Scientists Forum 2017; 107101D (2018) https://doi.org/10.1117/12.2317409
Event: Young Scientists Forum 2017, 2017, Shanghai, China
Abstract
In this paper, a novel method is proposed, which can simulate satellite platform micro-vibration and test the impact of satellite micro-vibration on imaging quality of space optical remote sensor on ground. The method can generate micro-vibration of satellite platform in orbit from vibrational degrees of freedom, spectrum, magnitude, and coupling path. Experiment results show that the relative error of acceleration control is within 7%, in frequencies from 7Hz to 40Hz. Utilizing this method, the system level test about the micro-vibration impact on imaging quality of space optical remote sensor can be realized. This method will have an important applications in testing micro-vibration tolerance margin of optical remote sensor, verifying vibration isolation and suppression performance of optical remote sensor, exploring the principle of micro-vibration impact on imaging quality of optical remote sensor.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yingying Gu, Yingying Gu, Li Wang, Li Wang, Qingwen Wu, Qingwen Wu, } "A micro-vibration generated method for testing the imaging quality on ground of space remote sensing", Proc. SPIE 10710, Young Scientists Forum 2017, 107101D (5 March 2018); doi: 10.1117/12.2317409; https://doi.org/10.1117/12.2317409