26 April 2018 Method for biological tissue temperature measuring in the area of laser radiation exposure with a small size beam profile during laser welding
Dmitrii I. Ryabkin
Author Affiliations +
Abstract
Connection is not strong enough In case of insufficient or excessive temperature of the laser welding. As a result, the temperature measurement in laser welding is an important problem. Measurement area surface is small (3.12 mm2) and measurements shall be carried out by a Non-contact method, which makes them challenging. Method of temperature measurement by an infrared sensor in two positions has been offered. This method allows you to measure the temperature at a distance of up to 5 cm from the measured area with an accuracy of 8%.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dmitrii I. Ryabkin "Method for biological tissue temperature measuring in the area of laser radiation exposure with a small size beam profile during laser welding", Proc. SPIE 10716, Saratov Fall Meeting 2017: Optical Technologies in Biophysics and Medicine XIX, 1071610 (26 April 2018); https://doi.org/10.1117/12.2316717