Paper
6 July 2018 Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
Lonie R. Salkowski, Mai Elezaby, Amy M. Fowler, Elizabeth Burnside, Ryan W. Woods, Roberta M. Strigel
Author Affiliations +
Proceedings Volume 10718, 14th International Workshop on Breast Imaging (IWBI 2018); 1071820 (2018) https://doi.org/10.1117/12.2318059
Event: The Fourteenth International Workshop on Breast Imaging, 2018, Atlanta, Georgia, United States
Abstract
The Enhancing Quality Using the Inspection Program (EQUIP) augments the FDA/MQSA program to ensure image quality review and implementation of corrective processes. In our screening mammography program, we compared technical recalls between digital breast tomosynthesis (DBT) and 2D full-field digital mammography (FFDM). This HIPAA-compliant study was exempt from IRB review. In consecutive screening mammograms (October 2013 through December 2017), prospectively recorded technical recalls were compared for imaging modality (FFDM, DBT+FFDM, DBT+synthesized mammography (SynM)), images requested, and indication(s) for technical recall (motion, positioning, technical/artifact). Chi-squared tests evaluated statistical significance between proportions. Of 48,324 screening mammograms, 277 (0.57%) patients were recalled for 360 indications with 371 repeated views. There were significantly less recalls among DBT exams compared to FFDM (X2 = 25.239; p=0<0.001). Overall 98 (27.2%) technical recalls were for motion, 192 (53.3%) positioning, and 70 (19.4%) technique/artifacts. Of these, 91 (31.1%) FFDM indications were for motion, 138 (47.1%) positioning, and 64 (21.8%) technique/artifacts. For DBT+FFDM there were 7 (15.6%) for motion, 35 (77.8%) positioning, and 3 (6.7%) technique/artifacts, compared to DBT+SynM with 0 (0%) indications for motion, 19 (86.4%) positioning, and 3 (13.6%) technique/artifacts. There were significant differences in the indications for technical recall prior to and after implementing DBT+SynM (X2 = 18.719; p<0.001). Technical recalls declined significantly with the inclusion of DBT (SynM/FFDM) as compared to FFDM alone; with recalls for motion demonstrating the greatest decrease. Positioning remains a dominant factor for technical recall regardless of modality, supporting the opportunity for continued technologist education in positioning to decrease technical recalls.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lonie R. Salkowski, Mai Elezaby, Amy M. Fowler, Elizabeth Burnside, Ryan W. Woods, and Roberta M. Strigel "Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls", Proc. SPIE 10718, 14th International Workshop on Breast Imaging (IWBI 2018), 1071820 (6 July 2018); https://doi.org/10.1117/12.2318059
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Digital breast tomosynthesis

Mammography

Image quality

Digital mammography

Breast

Cancer

Breast imaging

Back to Top