Paper
25 September 2018 Efficacy of the CERES internal calibration system
G. Louis Smith, Kory J. Priestley, Susan Thomas, Janet L. Davis, Z. Peter Szewczyk
Author Affiliations +
Abstract
The objective of the Clouds and Earth Radiant Energy System (CERES) scanning radiometer is to measure solar radiation reflected from the Earth, outgoing longwave radiation (OLR) from the Earth and radiation from the 10 to 12 micron longwave window. It has a shortwave channel, a total channel and a window channel. A Shortwave Incandescent Calibration Source (SWICS) is used to calibrate the Shortwave channel and Internal Black Bodies are used for the total and window channels. These three devises make up the Internal Calibration System (ICS) for the instrument. There is no on-board method for checking the shortwave response of the total channel. This response must be deduced by use of vicarious targets such as deep convective clouds. The CERES Flight Models 1 and 2 have been operating in orbit on the Terra spacecraft since 2000 and FM-3 and -4 since 2002 on Aqua. FM-5 flew in 2011 on Suomi-NPP. The last CERES instrument, FM-6, went into orbit in 2017 on the NOAA-20 satellite. There are now adequate data from the in-orbit calibration and validation work to evaluate the efficacy of the Internal Calibration System. After the calibrations are changed and following a period of operation, validation studies are used to produce revised calibrations. Validation methods include comparing measurements among the instruments as they observe the same scenes from the same directions within a short time. Another method is to compute the Tropical Mean, which is the average OLR between 30oN and 30oS. The Tropical Mean has been noted to be constant over the data period. The difference between the revised calibrations and the calibrations indicated by the ICS is a measure of the efficacy of the ICS. The ICS results and the calibrations from the broader study are compared herein. These differences are of the order of 1/4%.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. Louis Smith, Kory J. Priestley, Susan Thomas, Janet L. Davis, and Z. Peter Szewczyk "Efficacy of the CERES internal calibration system", Proc. SPIE 10785, Sensors, Systems, and Next-Generation Satellites XXII, 107851D (25 September 2018); https://doi.org/10.1117/12.2325847
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Shortwaves

Black bodies

Space operations

Solar radiation

Sensors

Lamps

RELATED CONTENT

Early trends on the Clouds and the Earth's Radiant Energy...
Proceedings of SPIE (September 07 2018)
Method for comparison of GERB and CERES radiances
Proceedings of SPIE (February 02 2004)
CERES/TRMM mission: early results
Proceedings of SPIE (December 14 1998)

Back to Top