12 December 2018 Research on multi-channel gain response nonuniformity correction technique for x-ray single-photon detection
Author Affiliations +
Proceedings Volume 10846, Optical Sensing and Imaging Technologies and Applications; 108462F (2018) https://doi.org/10.1117/12.2505464
Event: International Symposium on Optoelectronic Technology and Application 2018, 2018, Beijing, China
Abstract
X-ray single photon detection system convert the x-ray single photon to electrical signal for x-ray pulsar detection, etc., which commonly use detectors as SI-APD (Silicon - avalanche photodiode), SDD (Silicon drift detector), Si-PIN (Silicon PIN photodiode). The x-ray pulsar detection requires higher time-accuracy sensor corresponding to only one pixel. The energy of x-ray pulsar is very weak, approximately 2.3 counts/s•cm2 in LEO(Low earth orbit). In order to improve the efficiency of detection, detection array of multiple detectors is used to increase the effective detection area. The project of this paper selected 8×10 SDD sensor array. Each detector has independent readout circuit. Therefore, system gain and response time are different, resulting in nonuniform response to homologous target, this nonuniformity includes the gain response nonuniformity and the time response nonuniformity, in this paper, the gain response nonuniformity correction method is discussed. The usual method of gain response nonuniformity correction is using the signal source as the circuit input instead of the detector, which has inevitable consequence: the signal source must have extremely high precision and the signal Integrity, such as cable interface or connection distance, is indeed quite sensitive because of the huge gain of the single photon detector circuit, which is usually thousand-fold. Moreover, the usual calibration method can’t correct the detector's own response nonuniformity, and the efficiency is low through the one-by-one correction. In this paper, the "characteristic peak correction method for specific target materials" is proposed, and the implementation of the method is as follows: bombard the characteristic target using high-energy x-ray source (>40keV), get the target material characteristic peak by calculating the amplitude histogram of the output signal (characterization of x-ray Single photon energy), and obtain the correction coefficient after normalization. For example, the Fe Target has main characteristic peak of Kα 6.494keV, Kβ 7.058keV as well as impurities characteristic peak of 3.692keV (Ca), 2.014keV(P), 0.277keV(C). The correction coefficient can be obtained by using least squares method. The correction method calibrates the nonuniformity of 80 detectors and obtains the correction parameters of different detectors at the same time. The experimental results show that the correction accuracy of the characteristic peak correction method for specific targets is better than 0.5%, which is much higher than the traditional method of signal source correction. The correction system for this paper uses FPGA+MRAM architecture, where the MRAM is used to store correction parameters, and to achieve real-time corrections in orbit. The Simulink-SG Modular design language is used. The MRAM is especially used to save the correction parameters, so that uploading correction parameters in orbit is available. Through the specific target detection in orbit and the ‘characteristic peak correction method for specific target materials ’, the correction can be finished in orbit, that ensures the calibration accuracy of the X-ray pulsar detection system at the end of life.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Long Dong and Feiran Zhang "Research on multi-channel gain response nonuniformity correction technique for x-ray single-photon detection ", Proc. SPIE 10846, Optical Sensing and Imaging Technologies and Applications, 108462F (12 December 2018); https://doi.org/10.1117/12.2505464
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-ray detectors

X-rays

Calibration

Pulsars

Field programmable gate arrays

Nonuniformity corrections

RELATED CONTENT

SphinX x-ray spectrophotometer
Proceedings of SPIE (November 07 2012)
FPGA based charge fast histogramming for GEM detector
Proceedings of SPIE (October 25 2013)
Fast modular data acquisition system for GEM-2D detector
Proceedings of SPIE (November 25 2014)
First results from the OGRESS sounding rocket payload
Proceedings of SPIE (September 18 2015)

Back to Top