25 May 1989 High Speed Image Reconstruction Display For PACS
Author Affiliations +
Abstract
This paper describes our new high-speed image reconstruction display. This display reconstructs high-quality images using a hybrid algorithm which combines DCT and BTC methods, and communicates with the host computer at high speed through a BMC. To test the display's performance, we developed a prototype using this display and a main frame computer (Fujitsu M-340). Compressed images stored in the host's database are transferred to the displays via the BMC, and reconstructed using its local function. Experiment showed the display to be effective: It takes less than 5 seconds for a 10 to 1 compressed image to be transferred and reconstructed the image, while taking 10 seconds for the original image.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Morito Shiohara, Yukihiro Nakagawa, Toshiyuki Gotoh, Masatoshi Komeichi, and Ryuichiro Ohta "High Speed Image Reconstruction Display For PACS", Proc. SPIE 1092, Medical Imaging III: Image Processing, (25 May 1989); doi: 10.1117/12.953252; https://doi.org/10.1117/12.953252