1 March 2019 Trade-off between spatial details and motion artifact in multi-detector CT: A virtual clinical trial with 4D textured human models
Author Affiliations +
Abstract
In Computed Tomography (CT) imaging, high pitch and wide beam collimations accelerate imaging acquisitions and thus reduce motion artifacts. However, increasing pitch and collimation impact acquisition geometry and thus spatial quality of the images. The purpose of this study was to quantify the effects of pitch and beam collimation on image quality using a realistic virtual clinical trial (VCT) construct. The study used extended-cardio torso (XCAT) phantoms enhanced by synthesizing intra-organ heterogeneities within the lungs and bones. Different amounts of cardiac and respiratory motion were simulated, including heart rates of 0, 60, 90, 120 beats per minute, and respiratory rates of 0, 8, 12, 16 breadths per minute. Each case was imaged using a realistic, scanner-specific, and rapid CT simulator setup based on the geometry and physics of a commercial CT scanner (Siemens Definition Flash), at 120 kV, under multiple pitch values, beam collimations, all at the same dose levels. With the knowledge of the ground truth, the quality of the acquired images was quantified by measuring root mean squared error (RMSE) in the lungs. In general, results indicated that RMSE was higher for the phantoms with more respiratory or cardiac motions. For the pitch experiment, images with higher pitch values had less in-plane motion artifacts. RMSE also increased with increasing the pitch. However, the slope of this trend was found to be a function of motion profile, showing the trade-off between motion artifacts and spatial detail loss. For the beam collimation experiment, no major change was observed in in-plane motion artifacts with changes in the beam collimation. RMSE was almost constant with the increase in beam collimation. This study demonstrates the utility of a realistic VCT construct in quantitative evaluation and optimization of CT imaging protocols, when designing such a trial is ethically-prohibitive, costly, and time-consuming.
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ehsan Abadi, W. Paul Segars, Brian Harrawood, Shobhit Sharma, Thomas Sauer, Anuj Kapadia, and Ehsan Samei "Trade-off between spatial details and motion artifact in multi-detector CT: A virtual clinical trial with 4D textured human models", Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 109482R (1 March 2019); https://doi.org/10.1117/12.2512891
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computed tomography

Collimation

Heart

Motion models

Lung

Monte Carlo methods

Clinical trials

Back to Top