11 September 1989 Transient Temperature Technique For Measuring Normal Spectral And Normal Total Emittance
Author Affiliations +
Abstract
Normal spectral and normal total emittance values were obtained for sapphire and translucent alumina using Fourier-transform infrared spectroscopy. Values were derived from radiance measurements in the spectral range of 5000 cm-1 to 400 cm-1, and in the temperature range of 900 K to 1450 K. Samples were dropped from a furnace into the nitrogen ambient of the spectrometer to the position where the internal globar source is normally focused. Temperatures were determined from radiance values at 1027 cm-1 where alumina has zero reflectivity and transmittance. Standard deviations of the total normal emittances, expressed as percentages of the average of three drops, were ≤3% of the averages.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert J. Tiernan, Robert J. Tiernan, James E. Saunders, James E. Saunders, } "Transient Temperature Technique For Measuring Normal Spectral And Normal Total Emittance", Proc. SPIE 1112, Window and Dome Technologies and Materials, (11 September 1989); doi: 10.1117/12.960782; https://doi.org/10.1117/12.960782