Paper
3 March 2020 Charge-shifting optical lock-in detection with shifted excitation Raman difference spectroscopy for the analysis of fluorescent heterogeneous samples
Kay Sowoidnich, Martin Maiwald, Bernd Sumpf, Michael Towrie, Pavel Matousek
Author Affiliations +
Abstract
Shifted excitation Raman difference spectroscopy (SERDS) is a powerful tool for the investigation of fluorescent samples such as biological materials. In case of rapidly changing emission backgrounds the efficiency of SERDS can however be limited as alternating detection of spectra excited at the two shifted laser wavelengths is usually restricted to sampling rates of less than 10 Hz. To overcome this issue, a novel optical lock-in detection approach enabling rapid SERDS operation in the kilohertz range using a custom 830-nm dual-wavelength diode laser and a specialized CCD enabling charge shifting on the CCD chip is presented. As an example of fluorescent and heterogeneous natural specimens, six mineral samples were selected and moved irregularly during spectral acquisition. Compared to conventional CCD read-out (operated at 5.4 Hz) the fast charge-shifting read-out performed at 1,000 Hz demonstrated superior reproducibility between repeat spectra. Using partial least squares-discriminant analysis an improved classification performance of the charge-shifting mode (sensitivity: 99 %, specificity: 94 %) over conventional read-out (sensitivity: 90 %, specificity: 92 %) was achieved. Translating the charge-shifting concept to sub-surface analysis using spatially offset Raman spectroscopy (SORS) enabled also the successful detection of charge-shifting SERDS-SORS spectra from a polytetrafluoroethylene layer concealed behind a 0.25 mm thick opaque heterogeneous layer. Chargeshifting SERDS-SORS results demonstrate two-fold improvement in signal-to-background-noise-ratio and match reference spectra much more closely. The charge-shifting approach shows large potential when rapidly changing background interference due to sample heterogeneity, dynamically evolving systems and ambient light variations presents a major challenges, e.g. in biological and biomedical applications.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kay Sowoidnich, Martin Maiwald, Bernd Sumpf, Michael Towrie, and Pavel Matousek "Charge-shifting optical lock-in detection with shifted excitation Raman difference spectroscopy for the analysis of fluorescent heterogeneous samples", Proc. SPIE 11236, Biomedical Vibrational Spectroscopy 2020: Advances in Research and Industry, 112360K (3 March 2020); https://doi.org/10.1117/12.2544752
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Raman spectroscopy

Charge-coupled devices

Laser resonators

Luminescence

Spectroscopy

Pulsed laser operation

Semiconductor lasers

Back to Top