16 March 2020 Slot-scan dual-energy measurement of bone mineral density on a robotic x-ray system
Author Affiliations +
Abstract
Purpose: We investigate the feasibility of slot-scan dual-energy x-ray absorptiometry (DXA) on robotic x-ray platforms capable of synchronized source and detector translation. This novel approach will enhance the capabilities of such platforms to include quantitative assessment of bone quality using areal bone mineral density (aBMD), normally obtained only with a dedicated DXA scanner. Methods: We performed simulation studies of a robotized x-ray platform that enables fast linear translation of the x-ray source and flat-panel detector (FPD) to execute slot-scan dual-energy (DE) imaging of the entire spine. Two consecutive translations are performed to acquire the low-energy (LE, 80 kVp) and high-energy (HE, 120 kVp) data in <15 sec total time. The slot views are corrected with convolution-based scatter estimation and backprojected to yield tiled long-length LE and HE radiographs. Projection-based DE decomposition is applied to the tiled radiographs to yield (i) aBMD measurements in bone, and (ii) adipose content measurement in bone-free regions. The feasibility of achieving accurate aBMD estimates was assessed using a high-fidelity simulation framework with a digital body phantom and a realistic bone model covering a clinically relevant range of mineral densities. Experiments examined the effects of slot size (1 – 20 cm), scatter correction, and patient size/adipose content (waist circumference: 77 – 95 cm) on the accuracy and reproducibility of aBMD. Results: The proposed combination of backprojection-based tiling of the slot views and DE decomposition yielded bone density maps of the spine that were free of any apparent distortions. The x-ray scatter increased with slot width, leading to aBMD errors ranging from 0.2 g/cm2 for a 5 cm slot to 0.7 g/cm2 for a 20 cm slot when no scatter correction was applied. The convolution-based correction reduced the aBMD error to within 0.02 g/cm2 for slot widths <10 cm. Reproducible aBMD measurements across a range of body sizes (aBMD variability <0.1 g/cm2) were achieved by applying a calibration based on DE adipose thickness estimates from peripheral body sites. Conclusion: The feasibility of accurate and reproducible aBMD measurements on an FPD-based x-ray platform was demonstrated using DE slot scan trajectories, backprojection-domain decomposition, scatter correction, and adipose precorrection.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
C. Zhao, C. Luckner, M. Herbst, S. Vogt, L. Ritschl, S. Kappler, J. H. Siewerdsen, and W. Zbijewski "Slot-scan dual-energy measurement of bone mineral density on a robotic x-ray system", Proc. SPIE 11312, Medical Imaging 2020: Physics of Medical Imaging, 1131205 (16 March 2020); https://doi.org/10.1117/12.2549631
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Bone

X-rays

Dual energy x-ray absorptiometry

Spine

Minerals

Robotics

Radiography

Back to Top