16 March 2020 Orthopedic and myopathic imaging with transmission ultrasound tomography: experimental verification, quantitative accuracy and clinical implications
Author Affiliations +
Abstract
Muscular Dystrophy (Duchenne) and osteoarthritis are important diseases requiring quantitative tissue measurement for accurate monitoring. MRI with Dixon Sequences, Nakagami statistics, elastography and radiography have been used in semi-quantitative modes to infer myopathy, articular cartilage damage, and exercise induced muscle damage. We establish the high resolution quantitative accuracy of transmission ultrasound imaging using both fresh and cadaver knee tissue. The use of fresh tissue obviates the possibility that cadaverous tissue has different speed of sound (SOS) values due to fixation. We show also that the fixation procedure changes the SOS values by about 0.1% to 0.4% fibroglandular tissue, fat and skin. The use of multiple transverse sections at varying distances from the tibiofemoral space ameliorates bias. Using a 6 mm diameter ROI at 20 successive levels, the SOS measured for the Vastus medialis was 1573 m/s with a 95% CI of +/-1.8 m/s. The average standard deviation (SD) for the ROI’s altogether was 25.9 m/s. The accepted SOS value for muscle from the IT’IS Foundation, Zurich, is 1588.4, SD = 21.6 m/s. Similar results for 6 mm diameter ROI’s in fat at successive transverse sections yields an average of 1438.7 m/s, the ROI SD’s averaged 20.5 m/s. The IT’IS values are 1440 m/s with SD 21.4 m/s. Cartilage gives similar agreement: literature value is 1660 m/s, and we measure 1655.4 m/s (SD 14.6) in 4 mm diameter ROI. We show regions that have no MR response yet are quantitatively imaged in 3D transmission ultrasound.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James Wiskin, Bilal Malik, Veena Theendakara, and John Klock "Orthopedic and myopathic imaging with transmission ultrasound tomography: experimental verification, quantitative accuracy and clinical implications", Proc. SPIE 11319, Medical Imaging 2020: Ultrasonic Imaging and Tomography, 113190W (16 March 2020); https://doi.org/10.1117/12.2549759
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Ultrasonography

Magnetic resonance imaging

Scanners

Cartilage

Image segmentation

Bone

Back to Top