Poster
13 December 2020 Optimizing normal resistance of an x-ray transition edge sensor for frequency domain multiplexing
Kenichiro Nagayoshi, Martin de Wit, Luciano Gottardi, Marcel L. Ridder, Sven Visser, Emanuele Taralli, Hiroki Akamatsu, Marcel P. Bruijn, Jian-Rong Gao, Ruud W. M. Hoogeveen, Jan-Willem A. den Herder
Author Affiliations +
Conference Poster
Abstract
Athena is an ESA-led space telescope to be launched in the early 2030s. The X-ray Integral Field Unit (X-IFU) on board of the Athena mission is an X-ray imaging spectrometer, sensitive to 0.2-12 keV X-rays. The main sensor of the X-IFU is an array of ~3200 closely-packed superconducting transition-edge sensor (TES) microcalorimeters with X-ray absorbers. The X-IFU provides a breakthrough spectral resolution of 2.5 eV (full width at half maximum; FWHM) at 6 keV, which enables us to access unrevealed properties of the hot gases that are formed at every level of the hierarchical structure of the universe. At SRON, we are developing Frequency Division Multiplexing (FDM) readout with SQUID amplifiers as a baseline technology for the X-IFU. In the FDM system, the microcalorimeter pixels are AC-biased at different frequencies from 1 to 5 MHz. Therefore, it is crucial to minimize frequency-dependent phenomena because it causes non-linearity effects in the detector response and degrades the spectral resolution. Theoretical analyses have shown that this non-linearity is caused by weak-link behavior, induced by superconducting leads and can be mitigated by increasing the normal resistance of the TES. We are also developing TES arrays based on a superconducting Ti/Au bi-layer with an Au absorber as a sensor backup technology for the X-IFU. We have recently fabricated TES calorimeters with large variation of normal resistance from 25 to 150 mΩ by changing the width and aspect ratio of the bi-layer. The TESes with 117 and 150 mΩ have shown a promising spectral performance of below 2 eV (FWHM) at 6 keV. However, we still see that the detector response is affected by the weak-link behavior, especially at high frequency regime. In this paper, we briefly summarize our results with a focus on the spectral performance and the detector responsivity for each TES design. We also present our recent works on fabrication related to a superconducting wiring process, which would be useful for further reduction of the weak-link effects.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kenichiro Nagayoshi, Martin de Wit, Luciano Gottardi, Marcel L. Ridder, Sven Visser, Emanuele Taralli, Hiroki Akamatsu, Marcel P. Bruijn, Jian-Rong Gao, Ruud W. M. Hoogeveen, and Jan-Willem A. den Herder "Optimizing normal resistance of an x-ray transition edge sensor for frequency domain multiplexing", Proc. SPIE 11444, Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray, 114444C (13 December 2020); https://doi.org/10.1117/12.2562782
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Sensors

Space observatories

Superconductors

X-ray imaging

Fused deposition modeling

Resistance

Back to Top