13 December 2020 HARMONI first light spectroscopy for the ELT: geometrical calibration in the data reduction software
Author Affiliations +
Conference Poster
Abstract
HARMONI is the first light visible and near-IR integral field spectrograph for the ELT. It covers a large spectral range from 450nm to 2450nm with resolving powers from R (≡λ/Δλ) 3500 to 18000 and spatial sampling from 60mas to 4mas. It can operate in two Adaptive Optics modes - SCAO (including a High Contrast capability) and LTAO - or with NOAO. The project is preparing for Final Design Reviews. HARMONI slices the input light beam in subfields and then into slitlets and rearranges them to obtain spectra on its detectors. The Data Reduction software (DRS) handles calibration and scientific raw data from HARMONI and computes a fully reduced and calibrated science data cube. The challenge is to develop robust methods suitable for each of the 44 scale/band combinations of HARMONI. The geometrical calibration, one of the steps of the DRS, determines the coordinate transformation from detector pixels to wavelength and relative spatial position in the input focal plane. This paper provides a mathematical description of the algorithms involved in the geometrical calibration and presents validations on mock data simulated with the HARMONI Instrument Numerical Model (HINM). Briefly, to cope with a possible overlap of slitlets, we locate the slitlets using a global fitting method on flat-field exposures. The wavelength solution is computed using arc exposures. To compute the geometrical transformation we choose to use specific masks illuminated with a white continuum lamp. A trace mask exposure provides the transformation along the slitlets. A pinhole mask exposure determines the transformation in the perpendicular direction by fitting the flux within each slitlet.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Laure Piqueras, Aurélien Jarno, Louise Friot-Giroux, Thomas Béchet, Javier Piqueras López, Arlette Pécontal, Johan Richard, Nicolas Bouché, Niranjan A. Thatte, and Matthias Tecza "HARMONI first light spectroscopy for the ELT: geometrical calibration in the data reduction software", Proc. SPIE 11452, Software and Cyberinfrastructure for Astronomy VI, 114522T (13 December 2020); https://doi.org/10.1117/12.2560485
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Spectroscopy

Data modeling

Sensors

Visible radiation

Adaptive optics

Computer simulations

RELATED CONTENT

HARMONI at ELT: Getting to the Diffraction limit!
Proceedings of SPIE (January 01 1900)
The opto mechanical design of HARMONI a first light...
Proceedings of SPIE (September 24 2012)
The X-shooter pipeline
Proceedings of SPIE (July 29 2010)
CRIRES: commissioning and first science results
Proceedings of SPIE (July 25 2008)

Back to Top