Poster + Presentation + Paper
13 December 2020 Calibration of QUBIC: The Q and U bolometric interferometer for cosmology
J. D. Murphy, D. Burke, M. M. Gamboa Lerena, J.-Ch. Hamilton, L. Mousset, M. De Petris, C. O'Sullivan, S. A. Torchinsky, P. Ade, J. G. Alberro, A. Almela, G. Amico, L. H. Arnaldi, D. Auguste, J. Aumont, S. Azzoni, S. Banfi, B. Bélier, E. S. Battistelli, A. Baù, D. Bennett, L. Bergé, P. de Bernardis, J.-Ph. Bernard, M. Bersanelli, M.-A. Bigot-Sazy, J. Bonaparte, J. Bonis, E. Bunn, D. Buzi, F. Cavaliere, P. Chanial, C. Chapron, R. Charlassier, A. C. Cobos Cerutti, F. Columbro, A. Coppolecchia, G. D'Alessandro, G. De Gasperis, M. De Leo, S. Dheilly, C. Duca, L. Dumoulin, A. Etchegoyen, A. Fasciszewski, L. P. Ferreyro, D. Fracchia, C. Franceschet, K. M. Ganga, B. García, M. E. García Redondo, M. Gaspard, D. Gayer, M. Gervasi, M. Giard, V. Gilles, Y. Giraud-Heraud, L. Grandsire, M. Gómez Berisso, M. González, M. Gradziel, M. R. Hampel, D. Harari, S. Henrot-Versillé, F. Incardona, E. Jules, J. Kaplan, C. Kristukat, L. Lamagna, S. Loucatos, T. Louis, B. Maffei, S. Marnieros, W. Marty, A. Mattei, A. May, M. McCulloch, L. Mele, S. Masi, D. Melo, A. Mennella, L. Montier, L. M. Mundo, J. A. Murphy, F. Nati, E. Olivieri, C. Oriol, A. Paiella, F. Pajot, A. Passerini, H. Pastoriza, A. Pelosi, C. Perbost, M. Perciballi, F. Pezzotta, F. Piacentini, M. Piat, L. Piccirillo, G. Pisano, M. Platino, G. Polenta, D. Prêle, R. Puddu, D. Rambaud, E. Rasztocky, P. Ringegni, G. E. Romero, J. M. Salum, C. Scóccola, A. Schillaci, S. Scully, S. Spinelli, G. Stankowiak, M. Stolpovskiy, A. D. Supanitsky, A. Tartari, J.-P. Thermeau, P. Timbie, M. Tomasi, G. Tucker, C. Tucker, D. Viganò, N. Vittorio, F. Voisin, F. Wicek, M. Wright, M. Zannoni, A. Zullo
Author Affiliations +
Conference Poster
Abstract
QUBIC (a Q and U Bolometric Interferometer for Cosmology) is a next generation cosmology experiment designed to detect the B-mode polarisation of the Cosmic Microwave Background (CMB). A B-mode detection is hard evidence of Inflation in the ΛCDM model. QUBIC aims to accomplish this by combining novel technologies to achieve the sensitivity required to detect the faint B-mode signal. QUBIC uses technologies such as a rotating half-wave plate, cryogenics, interferometric horns with self-calibration switches and transition edge sensor bolometers. A Technical Demonstrator (TD) is currently being calibrated in APC in Paris before observations in Argentina in 2021. As part of the calibration campaign, the spectral response of the TD is measured to test and validate QUBIC's spectro-imaging capability. This poster gives an overview of the methods used to measure the spectral response and a comparison of the instrument data with theoretical predictions and optical simulations.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J. D. Murphy, D. Burke, M. M. Gamboa Lerena, J.-Ch. Hamilton, L. Mousset, M. De Petris, C. O'Sullivan, S. A. Torchinsky, P. Ade, J. G. Alberro, A. Almela, G. Amico, L. H. Arnaldi, D. Auguste, J. Aumont, S. Azzoni, S. Banfi, B. Bélier, E. S. Battistelli, A. Baù, D. Bennett, L. Bergé, P. de Bernardis, J.-Ph. Bernard, M. Bersanelli, M.-A. Bigot-Sazy, J. Bonaparte, J. Bonis, E. Bunn, D. Buzi, F. Cavaliere, P. Chanial, C. Chapron, R. Charlassier, A. C. Cobos Cerutti, F. Columbro, A. Coppolecchia, G. D'Alessandro, G. De Gasperis, M. De Leo, S. Dheilly, C. Duca, L. Dumoulin, A. Etchegoyen, A. Fasciszewski, L. P. Ferreyro, D. Fracchia, C. Franceschet, K. M. Ganga, B. García, M. E. García Redondo, M. Gaspard, D. Gayer, M. Gervasi, M. Giard, V. Gilles, Y. Giraud-Heraud, L. Grandsire, M. Gómez Berisso, M. González, M. Gradziel, M. R. Hampel, D. Harari, S. Henrot-Versillé, F. Incardona, E. Jules, J. Kaplan, C. Kristukat, L. Lamagna, S. Loucatos, T. Louis, B. Maffei, S. Marnieros, W. Marty, A. Mattei, A. May, M. McCulloch, L. Mele, S. Masi, D. Melo, A. Mennella, L. Montier, L. M. Mundo, J. A. Murphy, F. Nati, E. Olivieri, C. Oriol, A. Paiella, F. Pajot, A. Passerini, H. Pastoriza, A. Pelosi, C. Perbost, M. Perciballi, F. Pezzotta, F. Piacentini, M. Piat, L. Piccirillo, G. Pisano, M. Platino, G. Polenta, D. Prêle, R. Puddu, D. Rambaud, E. Rasztocky, P. Ringegni, G. E. Romero, J. M. Salum, C. Scóccola, A. Schillaci, S. Scully, S. Spinelli, G. Stankowiak, M. Stolpovskiy, A. D. Supanitsky, A. Tartari, J.-P. Thermeau, P. Timbie, M. Tomasi, G. Tucker, C. Tucker, D. Viganò, N. Vittorio, F. Voisin, F. Wicek, M. Wright, M. Zannoni, and A. Zullo "Calibration of QUBIC: The Q and U bolometric interferometer for cosmology", Proc. SPIE 11453, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X, 114532G (13 December 2020); https://doi.org/10.1117/12.2560172
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Interferometers

Bolometers

Data modeling

Polarization

Code division multiplexing

Microwave radiation

RELATED CONTENT


Back to Top