15 February 2021 Effects of x-ray scatter in quantitative dual-energy imaging using dual-layer flat panel detectors
Author Affiliations +
Abstract
Purpose: We compare the effects of scatter on the accuracy of areal bone mineral density (BMD) measurements obtained using two flat-panel detector (FPD) dual-energy (DE) imaging configurations: a dual-kV acquisition and a dual-layer detector. Methods: Simulations of DE projection imaging were performed with realistic models of x-ray spectra, scatter, and detector response for dual-kV and dual-layer configurations. A digital body phantom with 4 cm Ca inserts in place of vertebrae (concentrations 50 - 400 mg/mL) was used. The dual-kV configuration involved an 80 kV low-energy (LE) and a 120 kV high-energy (HE) beam and a single-layer, 43x43 cm FPD with a 650 μm cesium iodide (CsI) scintillator. The dual-layer configuration involved a 120 kV beam and an FPD consisting of a 200 μm CsI layer (LE data), followed by a 1 mm Cu filter, and a 550 μm CsI layer (HE data). We investigated the effects of an anti-scatter grid (13:1 ratio) and scatter correction. For the correction, the sensitivity to scatter estimation error (varied ±10% of true scatter distribution) was evaluated. Areal BMD was estimated from projection-domain DE decomposition. Results: In the gridless dual-kV setup, the scatter-to-primary ratio (SPR) was similar for the LE and HE projections, whereas in the gridless dual layer setup, the SPR was ~26% higher in the LE channel (top CsI layer) than in the HE channel (bottom layer). Because of the resulting bias in LE measurements, the conventional projection-domain DE decomposition could not be directly applied to dual-layer data; this challenge persisted even in the presence of a grid. In contrast, DE decomposition of dual-kV data was possible both without and with the grid; the BMD error of the 400 mg/mL insert was -0.4 g/cm2 without the grid and +0.3 g/cm2 with the grid. The dual-layer FPD configuration required accurate scatter correction for DE decomposition: a -5% scatter estimation error resulted in -0.1 g/cm2 BMD error for the 50 mg/mL insert and a -0.5 g/cm2 BMD error for the 400 mg/mL with a grid, compared to <0.1 g/cm2 for all inserts in a dual-kV setup with the same scatter estimation error. Conclusion: This comparative study of quantitative performance of dual-layer and dual-kV FPD-based DE imaging indicates the need for accurate scatter correction in the dual-layer setup due to increased susceptibility to scatter errors in the LE channel.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chumin Zhao, Stephen Z. Liu, Wenying Wang, Magdalena Herbst, Thomas Weber, Sebastian Vogt, Ludwig Ritschl, Steffen Kappler, J. Webster Stayman, Jeffrey H. Siewerdsen, and Wojciech Zbijewski "Effects of x-ray scatter in quantitative dual-energy imaging using dual-layer flat panel detectors", Proc. SPIE 11595, Medical Imaging 2021: Physics of Medical Imaging, 115952A (15 February 2021); https://doi.org/10.1117/12.2581822
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Dual energy imaging

X-ray detectors

X-ray imaging

X-rays

Error analysis

Cesium

Back to Top